2001
DOI: 10.1016/s0378-4347(01)00393-0
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative detection of bisphenol A and bisphenol A diglycidyl ether metabolites in human plasma by liquid chromatography–electrospray mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
42
2
3

Year Published

2002
2002
2016
2016

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 74 publications
(47 citation statements)
references
References 22 publications
0
42
2
3
Order By: Relevance
“…Unlike these findings, we could detect BPA at a broader range in serum, not just at concentrations around 1 ng/mL. In contrast to our study and the reports of Inoue et al (2001) and Ohkuma H. et al (2002), Fung et al (2000 did not detect BPA in serum of 40 healthy subjects when investigating the pharmacokinetics of BPA released from a dental sealant.…”
Section: Discussioncontrasting
confidence: 99%
“…Unlike these findings, we could detect BPA at a broader range in serum, not just at concentrations around 1 ng/mL. In contrast to our study and the reports of Inoue et al (2001) and Ohkuma H. et al (2002), Fung et al (2000 did not detect BPA in serum of 40 healthy subjects when investigating the pharmacokinetics of BPA released from a dental sealant.…”
Section: Discussioncontrasting
confidence: 99%
“…Serum BPA levels in this sample of pregnant women appeared high, contrasting with findings of 1.49 ± 0.11 and 0.64 ± 0.10 ng/ml, respectively, in a population of Japanese men and women [32]. Studies have reported blood BPA concentrations ranging from below 1 ng/ml to 19 ng/ml in individuals with no intentional exposure [33][34][35], although this wide variation may be related to the different BPA quantification method used. These www.witpress.com, ISSN 1743-3541 (on-line) data suggest that children may also be exposed to BPA during pregnancy.…”
Section: Discussioncontrasting
confidence: 97%
“…GC-MS analysis was performed using a 6890 Agilent (Agilent Technologies, Wilmington, USA) gas chromatograph with a 7683 series injector and a quadruple mass filter 5976 network mass selective detector (MSD) following a previously published method [33]. In brief, a ZB-5 MS Zebron capillary column (30 m×0.25 mm i.d.…”
Section: Apparatus: Gas Chromatography-mass Spectrometry Analysismentioning
confidence: 99%
“…Seventeen studies have measured BPA in blood and serum samples from healthy male and nonpregnant female adults (Dirtu et al 2008;Fung et al 2000;He et al 2009;Hiroi et al 2004;Ikezuki et al 2002;Inoue et al 2000Inoue et al , 2001Kaddar et al 2009;Kuroda et al 2003;Liu et al 2007;Sajiki et al 1999;Sugiura-Ogasawara et al 2005;Takeuchi and Tsutsumi 2002;Takeuchi et al 2004;Volkel et al 2005;Yang M et al 2009;Yoshimura et al 2002) (Table 3). Of these studies, five used ELISA, one used a radioimmunoassay (RIA), and the remainder used analytical chemistry to assess BPA concentrations.…”
Section: Internal Dosage Assessment From Blood Measures Of Bpamentioning
confidence: 99%