2012
DOI: 10.1186/2191-219x-2-45
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative capabilities of four state-of-the-art SPECT-CT cameras

Abstract: BackgroundFour state-of-the-art single-photon emission computed tomography-computed tomography (SPECT-CT) systems, namely Philips Brightview, General Electric Discovery NM/CT 670 and Infinia Hawkeye 4, and Siemens Symbia T6, were investigated in terms of accuracy of attenuation and scatter correction, contrast recovery for small hot and cold structures, and quantitative capabilities when using their dedicated three-dimensional iterative reconstruction with attenuation and scatter corrections and resolution rec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
51
0
1

Year Published

2013
2013
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 64 publications
(55 citation statements)
references
References 25 publications
0
51
0
1
Order By: Relevance
“…Two facets of the design of the integrated CT components can be identified: first, SPECT/CT systems include fullydiagnostic CT systems with fast-rotation detectors that permit the simultaneous acquisition of 16 or 64 detector rows, while the X-ray tubes provide sufficient tube voltages together with high tube current and automatic exposure control (General Electric Discovery NM/CT 670 and the Siemens Symbia [32]). These systems also support advanced CT capabilities such as cardiac gating, calcium scoring and iterative reconstruction [18,33].…”
Section: Spect/ctmentioning
confidence: 99%
See 1 more Smart Citation
“…Two facets of the design of the integrated CT components can be identified: first, SPECT/CT systems include fullydiagnostic CT systems with fast-rotation detectors that permit the simultaneous acquisition of 16 or 64 detector rows, while the X-ray tubes provide sufficient tube voltages together with high tube current and automatic exposure control (General Electric Discovery NM/CT 670 and the Siemens Symbia [32]). These systems also support advanced CT capabilities such as cardiac gating, calcium scoring and iterative reconstruction [18,33].…”
Section: Spect/ctmentioning
confidence: 99%
“…On the other hand, SPECT/CT systems include rotating SPECT components that come with adapted rotation times and dose-optimized acquisition modes, while employing CTtype components with limited acquisition flexibility, such as lower tube voltages and currents (General Electric Hawkeye, Philips Brightview-XCT [32]). The Hungarian company Mediso, for example, offers a triple-modality SPECT/CT/PET system (Mediso AnyScan), which combines all three modalities within a single device (Figure 1).…”
Section: Spect/ctmentioning
confidence: 99%
“…In our experience, the system behaviour is stable over time. The sensitivity can vary between SPECT systems from different vendors and for differently sized phantoms as Seret et al [19] have shown. They report relatively small error bars (−3.83%, 4.15% and 0.76%) for a NEMA standard phantom with a SPECT/CT Symbia system similar to those used in this study.…”
Section: Resultsmentioning
confidence: 99%
“…SPECT/CT hardware image fusion may allow precise three-dimensional anatomic localization of 99m Tcannexin A5 uptake and CT-based attenuation correction, and may significantly improve SPECT image quality with OSEM reconstruction and corrections for all imagedegrading factors [14,18,[78][79][80][81][82].…”
Section: Discussionmentioning
confidence: 99%