Abstract: The present study showed that it is possible to gain sensitivity when going to smaller scale LC-MS (UPLC-MS to μLC-MS). Due to the combination of a modified sample preparation approach and the application of μLC-MS a lower LOQ could be achieved for infliximab compared with a previously developed UPLC-MS method.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(12 citation statements)
references
References 30 publications
0
12
0
Order By: Relevance
“…Finally, the experimental ratios were assessed. With matching settings between non‐labeled analyte peptides and their SIL equivalents, the theoretical signal ratio between analyte and SIL IS for the 80 μg/mL calibration sample was calculated to be 9.2 according to the formula for absolute recovery 29 . This theoretical ratio only applies when the monitored product ions contain all the labels or none of the labels, see also the earlier discussion about the experimental analyte/SIL IS ratios for transitions with products ions that are partially labeled.…”
Section: Resultsmentioning
confidence: 99%
“…Finally, the experimental ratios were assessed. With matching settings between non‐labeled analyte peptides and their SIL equivalents, the theoretical signal ratio between analyte and SIL IS for the 80 μg/mL calibration sample was calculated to be 9.2 according to the formula for absolute recovery 29 . This theoretical ratio only applies when the monitored product ions contain all the labels or none of the labels, see also the earlier discussion about the experimental analyte/SIL IS ratios for transitions with products ions that are partially labeled.…”
Section: Resultsmentioning
confidence: 99%
“…The technique is a greener alternative too, as solvent waste is also much reduced, with one application reported as better than a 20-fold improvement against conventional flow [21]. There have been several recent reported applications of microflow [18,[20][21][22][23][24] and although not there in abundance as yet, usage is fully expected to increase as the technology becomes better accepted and its benefits fully realized across the industry.…”
Section: Scaling Down Lc-ms With Benefits Scaling Upmentioning
confidence: 99%
“…In recent years, the use of LC‐–MS/MS to quantify therapeutic proteins using a surrogate peptide after proteolytic digestion is growing in popularity quickly as a mainstream bioanalytical technique. Its advantages over LBAs are the capability to detect and quantify peptides in specific regions of the proteins for specificity, ability to resist interference from specific matrix components such as antidrug antibodies, feasibility of multiplex analysis, wider linear range, and rapid method development (particularly saving time in preparing antigens) (Kleinnijenhuis, Ingola, Toersche, van Holthoon, & van Dongen, 2016).…”