2014
DOI: 10.1016/j.acra.2014.06.005
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative Assessment of Effects of Motion Compensation for Liver and Lung Tumors in CT Perfusion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 18 publications
(8 citation statements)
references
References 22 publications
0
8
0
Order By: Relevance
“…and G.G., 25-year experience each) on a reference slice, where the tumour showed the widest area, similar to what was done in [ 20 , 27 , 28 ]. Then, for each lesion, the radiologists performed a 3D alignment according to the procedure described in [ 29 ]. In order to obtain the TCCs relative to each voxel, the values of the temporal sequence were fitted using the sigmoid-shape model, arising from the Hill Equation [ 30 ], and the random sampling method described in [ 31 ].…”
Section: Methodsmentioning
confidence: 99%
“…and G.G., 25-year experience each) on a reference slice, where the tumour showed the widest area, similar to what was done in [ 20 , 27 , 28 ]. Then, for each lesion, the radiologists performed a 3D alignment according to the procedure described in [ 29 ]. In order to obtain the TCCs relative to each voxel, the values of the temporal sequence were fitted using the sigmoid-shape model, arising from the Hill Equation [ 30 ], and the random sampling method described in [ 31 ].…”
Section: Methodsmentioning
confidence: 99%
“…where M is the number of samples of the TCC considered [23]. For each patient, the voxel-based baseline values and single and dual input perfusion parameters were computed for E 0 and each E τ exploiting the maximum slope method.…”
Section: Assessment Of Results and Statistical Analysesmentioning
confidence: 99%
“…A second set of approaches works in post-processing, relying on manual or automatic alignments methods [18,19], although in the literature there is a lack of standard or widely acknowledged registration algorithms [20,21]. Finally, a third group of recent approaches acts at the methodological level focusing on reliability issues in general, for instance, improving acquisition sampling to prevent the effects of motion [22], quantifying and removing residual artefacts [23,24], and providing measurements of perfusion reliability [25]. Nonetheless, all these problems are indissolubly related to the data quality issue and, ultimately, to the dose administered to patients.…”
Section: Introductionmentioning
confidence: 99%
“…Voxel-based BF values, expressed in mL/min/100 g, were computed for each slice, using an in-house algorithm developed in Matlab (MathWorks, Natick, MA), implementing the maximum slope method [35] and represented through the use of colorimetric maps. Misleading perfusion values computed on poorly representative TCCs (due to a bad fit) were excluded from the analysis according to what is reported in [16, 36], in order to obtain more reliable results. The corresponding voxels are displayed in the colour maps with the “pink” colour.…”
Section: Methodsmentioning
confidence: 99%