2015
DOI: 10.1002/jbio.201400153
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative and rapid estimations of human sub‐surface skin mass using ultra‐high‐resolution spectral domain optical coherence tomography

Abstract: Non-invasive and quantitative estimations for the delineation of sub-surface tumor margins could greatly aid in the early detection and monitoring of the morphological appearances of tumor growth, ensure complete tumor excision without the unnecessary sacrifice of healthy tissue, and facilitate post-operative follow-up for recurrence. In this study, a high-speed, non-invasive, and ultra-high-resolution spectral domain optical coherence tomography (UHR-SDOCT) imaging platform was developed for the quantitative … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 23 publications
(35 reference statements)
0
6
0
Order By: Relevance
“…Clear visualisation of a signal drop between Ep and D was depicted in the UHR-OCT images but no detailed delineation of where exactly to draw the DEJ on the OCT image was presented in these or in the ensuing studies. In parallel, other studies presented the disagreement on where exactly to draw the DEJ within the Ep-D signal transition region 5,31 . Several other groups did not introduce or explain their choice of DEJ definition in the OCT signal before deducting the Ep thickness 6,20,32,33 .…”
Section: The Skinmentioning
confidence: 99%
“…Clear visualisation of a signal drop between Ep and D was depicted in the UHR-OCT images but no detailed delineation of where exactly to draw the DEJ on the OCT image was presented in these or in the ensuing studies. In parallel, other studies presented the disagreement on where exactly to draw the DEJ within the Ep-D signal transition region 5,31 . Several other groups did not introduce or explain their choice of DEJ definition in the OCT signal before deducting the Ep thickness 6,20,32,33 .…”
Section: The Skinmentioning
confidence: 99%
“…Figure 10 shows the setup of the MFOCT system ( Kuo et al, 2016 ). The light source has a central wavelength of 1,275 nm and spectral bandwidth of 240 nm after passing through dichroic mirrors and a color filter, delivering an axial resolution of approximately 5 μm in air.…”
Section: Methodsmentioning
confidence: 99%
“…6. The detail of the system can be found elsewhere 35 . In short, a broadband (wavelength range: 650–1800 nm) supercontinuum fiber laser (SuperK Extreme, NKT Photonics, Denmark) was used as an illumination source in the present system.…”
Section: Methodsmentioning
confidence: 99%