2006
DOI: 10.1021/ac060707p
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative Analysis of Trace Chromium in Blood Samples. Combination of the Advanced Oxidation Process with Catalytic Adsorptive Stripping Voltammetry

Abstract: A new method for pretreating blood samples for trace Cr analysis is described. The Advanced Oxidation Process (AOP with H 2 O 2 and 5.5-W irradiation for 60 min) is used to remove biological/ organic species for subsequent analysis. Prior to the AOP pretreatment, acid (HNO 3 ) is used at pH 3.0 to inhibit the enzyme catalase in the blood samples. Catalytic Adsorptive Stripping Voltammetry (CAdSV) at a bismuth film electrode (BiFE) gives Cr concentration of 6.0 ± 0.3 ppb in the blood samples. This concentratio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
60
1
1

Year Published

2008
2008
2019
2019

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 58 publications
(63 citation statements)
references
References 45 publications
1
60
1
1
Order By: Relevance
“…Arguments such as possible sample loss, reaction with the container's surface, and incomplete ashing have been presented [23,28]. Yet many still regard dry ashing as a viable practice provided care is taken in the process [9][10][11][12]14,21,22,29].…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Arguments such as possible sample loss, reaction with the container's surface, and incomplete ashing have been presented [23,28]. Yet many still regard dry ashing as a viable practice provided care is taken in the process [9][10][11][12]14,21,22,29].…”
Section: Resultsmentioning
confidence: 99%
“…Intermittent stirring allowed even ashing and monitoring of the sample. Ashing was determined complete when the sample was a rust red-brown color, typical for iron oxides, and no black substance, indicating carbon, remained [21,22]. Total ashing time was dependent on the volume of sample in the evaporating dish.…”
Section: Methods a (New Procedure)mentioning
confidence: 99%
See 2 more Smart Citations
“…Thereafter, the nanoparticles were centrifuged at a speed of 12500 rpm for 15 min to remove free polymer conjugates, and washed once with Milli- The concentration of silver in the silver colloids and the uptake of AgNPs in cancer cells was also estimated using Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES). In order to estimate the silver content in cells, cells were deproteinized by a wet ashing procedure as described by Yong et al (Yong 2006). Briefly, FHAgNPs, FCAgNPs, FAgNPs (AgNPs self-assembled with FP but without DOX) and AgNPs (bare AgNPs) were incubated for 24 h with MES-SA, MES-SA/Dx5, SKOV3 and L1210 cells (at a cell density of 100,000 cells/ ml) at a final concentration of 32.5 ppb.…”
Section: Preparation Of Polymer Conjugate-self Assembled Agnpsmentioning
confidence: 99%