Quantitative accuracy improvement of laser-induced breakdown spectroscopy by a modified corner-cutting method for continuum background removal

Abstract: As a popular elemental analysis technique, laser-induced breakdown spectroscopy (LIBS) has been applied in many fields, including coal analysis, nuclear industry, deep-sea, and Mars exploration. LIBS spectra have a continuum...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 17 publications
0
2
0
Order By: Relevance
“…251 Initial studies with SiO 2 particles gave an upper LOD size of 1200 nm, compared with an estimate of <1000 nm for a cyclonic spray chamber, with 29 Si being the monitored isotope, and measured without the use of a collision cell as this has been reported to induce band broadening which impacts the lower and upper LOD size limits. When applied to the 27 Al signal arising from clay particles it was observed that particle above 420 nm, which were shown to be present by TEM analysis, were not detected. To test the assumption that the larger particles were not detected due to detector saturation, the instrument was signicantly detuned to reduce ion transmission.…”
Section: Nanostructuresmentioning
confidence: 96%
See 1 more Smart Citation
“…251 Initial studies with SiO 2 particles gave an upper LOD size of 1200 nm, compared with an estimate of <1000 nm for a cyclonic spray chamber, with 29 Si being the monitored isotope, and measured without the use of a collision cell as this has been reported to induce band broadening which impacts the lower and upper LOD size limits. When applied to the 27 Al signal arising from clay particles it was observed that particle above 420 nm, which were shown to be present by TEM analysis, were not detected. To test the assumption that the larger particles were not detected due to detector saturation, the instrument was signicantly detuned to reduce ion transmission.…”
Section: Nanostructuresmentioning
confidence: 96%
“…A paper by Hu et al reported methodology to improve accuracy by removing the continuum background signal . 27 A “moving average corner cutting” method was described in full. Results from LIBS analyses where no model was used, moving average corner cutting and from corner cutting alone were compared.…”
Section: Metalsmentioning
confidence: 99%