2019
DOI: 10.1002/mrm.28050
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative 3D myocardial perfusion with an efficient arterial input function

Abstract: Purpose The purpose of this study was to further develop and combine several innovative sequence designs to achieve quantitative 3D myocardial perfusion. These developments include an optimized 3D stack‐of‐stars readout (150 ms per beat), efficient acquisition of a 2D arterial input function, tailored saturation pulse design, and potential whole heart coverage during quantitative stress perfusion. Theory and Methods All studies were performed free‐breathing on a Prisma 3T MRI scanner. Phantom validation was us… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
24
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 16 publications
(24 citation statements)
references
References 83 publications
(166 reference statements)
0
24
0
Order By: Relevance
“…These studies sequentially acquire the slice groups at different cardiac phases. The 3D acquisitions [9][10][11][12] allow for acquisition of multiple slices at the same cardiac phase; however, the long temporal footprint (150-300 ms) may not be optimal for systolic imaging.…”
Section: Introductionmentioning
confidence: 99%
“…These studies sequentially acquire the slice groups at different cardiac phases. The 3D acquisitions [9][10][11][12] allow for acquisition of multiple slices at the same cardiac phase; however, the long temporal footprint (150-300 ms) may not be optimal for systolic imaging.…”
Section: Introductionmentioning
confidence: 99%
“…stack-of-stars) approach due to its similar distribution in 3D k-space. 27,46 This data-sampling scheme has the benefit of mitigating motion-induced temporal blurring, especially with respect to radial trajectory that has been proved to be robust to motion artifacts. 47 Data sampling and constrained reconstruction are intertwined.…”
Section: Discussionmentioning
confidence: 99%
“…The proposed sampling strategy may also benefit a 3D stack‐of‐radial (a.k.a. stack‐of‐stars) approach due to its similar distribution in 3D k ‐space 27,46 . This data‐sampling scheme has the benefit of mitigating motion‐induced temporal blurring, especially with respect to radial trajectory that has been proved to be robust to motion artifacts 47 …”
Section: Discussionmentioning
confidence: 99%
“…Only 3 slices were acquired during myocardial perfusion imaging. Additional studies are required to explore increasing slice coverage through simultaneous multi-slice 12,13 and 3-dimensional myocardial perfusion 11,[22][23][24][25] imaging. Myocardial blood flow (MBF) was not quantified for both free-running SPGR with and without non-selective RF.…”
Section: Discussionmentioning
confidence: 99%