2004
DOI: 10.1002/ffj.1334
|View full text |Cite
|
Sign up to set email alerts
|

Quantitation of suspected allergens in fragrances (Part I): evaluation of comprehensive two‐dimensional gas chromatography for quality control

Abstract: An evaluation of comprehensive two-dimensional (2D) gas chromatography (GC×GC) was performed to assess its suitability for the analysis of volatile fragrance components, recognized by the European Commission's Scientific Committee on Cosmetics and other Non-food Products (SCCNFP) as possible skin sensitizers. The 24 volatile components listed by the SCCNFP were baseline-resolved or better within one 30 min analysis. Highquality calibration data for standard mixtures were obtained, with R 2 > 0.998 over the con… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0
2

Year Published

2007
2007
2016
2016

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 59 publications
(25 citation statements)
references
References 33 publications
0
23
0
2
Order By: Relevance
“…The specificity of the method is a critical step in a validation procedure, and in particular for target analytes quantitation [24,25] and is one of the primary goals that can fruitfully be reached by proper selectivity tuning of the 2-D column stationary phase [26,27]. Widely used orthogonal stationary phase combinations, such as 1-D OV1/2-D CW20 M, are not effective enough in this connection, in particular with polar analytes (alcohols and some carbonyl-substituted derivatives) affected by a strong 2-D retention, mainly due to the inappropriate elution temperature of the 2-D column.…”
Section: Target-analysis: Suspected Allergens Quantitation In Medium-mentioning
confidence: 99%
“…The specificity of the method is a critical step in a validation procedure, and in particular for target analytes quantitation [24,25] and is one of the primary goals that can fruitfully be reached by proper selectivity tuning of the 2-D column stationary phase [26,27]. Widely used orthogonal stationary phase combinations, such as 1-D OV1/2-D CW20 M, are not effective enough in this connection, in particular with polar analytes (alcohols and some carbonyl-substituted derivatives) affected by a strong 2-D retention, mainly due to the inappropriate elution temperature of the 2-D column.…”
Section: Target-analysis: Suspected Allergens Quantitation In Medium-mentioning
confidence: 99%
“…Routine GC-MS can be used to analyse 24 out of these 26 allergens in consumer (and intermediate) products, but insufficient peak capacity and peak-shifting easily cause problems. On the other hand, GCÂGC on SPB-1 Â SupelcoWax-10 yields a satisfactory separation of all 24 allergens in a mere 30 min [94]. A baseline separation was effected for the often occurring α-and β-ionone from each other and from trace-level α-isomethylionone.…”
Section: Food Fat Oils Flavours and Fragrancesmentioning
confidence: 97%
“…[72][73][74][75][76][77][78] Na separação de voláteis de cachaça 79 foi relatada a possibilidade distinguir o tipo de madeira empregada no processo de envelhecimento; já para voláteis de uva 80 o perfil dos terpenos e seus derivados oxigenados pode ser empregado para traçar a origem da uva. Ainda, a separação e quantificação de alergênicos 46,47,[81][82][83] presentes em perfumes e cosméticos, bem como em óleos essenciais, também tem sido bastante investigada por GC x GC.…”
Section: Aplicações De Gc × Gcunclassified