2015
DOI: 10.1007/978-3-319-19387-8_240
|View full text |Cite
|
Sign up to set email alerts
|

Quantifying Blood-Oxygen Saturation Measurement Error in Motion Contaminated Pulse Oximetry Signals

Abstract: Abstract-Oxygen saturation measurements from pulse oximetry (SpO 2 ) can be unreliable in the presence of motion artifacts. While pulse oximetry is a crucial measurement in controlled environments, such as surgery or intensive care, its vulnerability to motion artifacts has slowed its adoption in wearable continuous monitoring devices. Measurement error can cause errors or delays in clinical decision-making. In remote monitoring applications, pulse oximeters should report measurement confidence along with SpO … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
2
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(8 citation statements)
references
References 4 publications
0
2
0
Order By: Relevance
“…Clarke et al managed to record clean PPG signals. After that, they contaminated the PPG signal by adding identical noise additive white Gaussian noise (AWGN) to both the red and infrared PPG signals [22]. The aim of Joseph et al is to determine the different parameters of PPG signal [23].…”
Section: Related Workmentioning
confidence: 99%
See 1 more Smart Citation
“…Clarke et al managed to record clean PPG signals. After that, they contaminated the PPG signal by adding identical noise additive white Gaussian noise (AWGN) to both the red and infrared PPG signals [22]. The aim of Joseph et al is to determine the different parameters of PPG signal [23].…”
Section: Related Workmentioning
confidence: 99%
“…They used the wavelet de-noising approach to remove AWGN from the synthetic PPG signal. In [10] and [22], the simulation was performed on the synthesized motion corrupted PPG signal, while we consider the practical motion corrupted PPG signal to develop our PO system. Ram et al proposed an adaptive step-size least mean squares adaptive filter to reduce the motion artifact corrupted PPG signal [24].…”
Section: Related Workmentioning
confidence: 99%
“…In sports that have a slow onset or a longer intensity as seen in our golf research, hypoxemia is less common. Therefore, we did not take measurements during the sport performance [12], but after 15 minutes, as it has been shown [21] that hypoxemia occurs during and after the immediate cessation of the sport performance [4].…”
Section: Introductionmentioning
confidence: 99%
“…The conventional SpO 2 calculation algorithm is evaluated without the aid of error mitigation techniques. Some of the results in this chapter have been disseminated in the author's conference publications [9,10].…”
Section: Introductionmentioning
confidence: 99%
“…14, 2014. [9] • G. W. J. Clarke, A. D. C. Chan, and A. Adler, "Quantifying Blood-Oxygen Saturation Measurement Error in Motion Contaminated Pulse Oximetry Signals,"World Congress on Medical Physics and Biomedical Engineering, 2015 [10].…”
mentioning
confidence: 99%