2021
DOI: 10.1016/j.jvs.2020.04.522
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of suprarenal aortic neck dilation after fenestrated endovascular aneurysm repair

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

8
20
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(29 citation statements)
references
References 22 publications
8
20
0
Order By: Relevance
“…Thus, our data do not yet provide enough information to suggest whether the existing common practice for oversizing should be altered. Although not significant, our results demonstrate a trend that wider preoperative proximal seal diameters are associated with increased risk of >10% PSD at one year, which is in conjunction with earlier findings for FEVAR 12,13,16 and standard infrarenal EVAR. 5 Such a relation was not visible in univariable analysis, which we believe is the result of the small variety in proximal seal diameter within the cohort, and as diameters differ greatly at different aortic levels.…”
Section: Discussionsupporting
confidence: 89%
See 4 more Smart Citations
“…Thus, our data do not yet provide enough information to suggest whether the existing common practice for oversizing should be altered. Although not significant, our results demonstrate a trend that wider preoperative proximal seal diameters are associated with increased risk of >10% PSD at one year, which is in conjunction with earlier findings for FEVAR 12,13,16 and standard infrarenal EVAR. 5 Such a relation was not visible in univariable analysis, which we believe is the result of the small variety in proximal seal diameter within the cohort, and as diameters differ greatly at different aortic levels.…”
Section: Discussionsupporting
confidence: 89%
“…The occurrence of PSD following FEVAR has been previously described by Tran et al in 43 FEVAR-patients. 13 Our study confirms the development of PSD at this aortic level with a larger sample size, but also demonstrated that proximal seal dilatation following FEVAR decelerates over time. The subsequent deceleration that we found is in concordance with previous studies on infrarenal EVAR 6 , and with Zetterval et al and Qaderi et al, who reported on proximal neck dilatation following FEVAR with physician modified endografts (PMEGs).…”
Section: Discussionsupporting
confidence: 84%
See 3 more Smart Citations