2015
DOI: 10.1016/j.foodchem.2014.10.103
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of sugars in wheat flours with an HPAEC-PAD method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
25
0
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 41 publications
(28 citation statements)
references
References 26 publications
1
25
0
1
Order By: Relevance
“…When higher concentrations were found, samples were previously diluted before being ianalysed. The within-run and the between-run precision of HPAEC-PAD analysis were all lower than 10% and are similar to those presented by Pico et al [6]. All of these parameters highlight the ability and the reliability of using HPAEC-PAD for the LoD, limit of detection; LoQ, limit of quantification; CV, coefficient of variation; GE, glucose equivalent; ME, maltose equivalent.…”
Section: Methods Validationsupporting
confidence: 84%
“…When higher concentrations were found, samples were previously diluted before being ianalysed. The within-run and the between-run precision of HPAEC-PAD analysis were all lower than 10% and are similar to those presented by Pico et al [6]. All of these parameters highlight the ability and the reliability of using HPAEC-PAD for the LoD, limit of detection; LoQ, limit of quantification; CV, coefficient of variation; GE, glucose equivalent; ME, maltose equivalent.…”
Section: Methods Validationsupporting
confidence: 84%
“…Another simple option suitable for determination of sugar class is high-performance anion exchange chromatography with pulsed amperometric detection (HPAEC-PAD). As in case of HPLC and CE, a derivatization step is not required, but experimental results proved that the technique is providing poor resolution for some components like sucrose (Pico et al 2015). Three different cyclitols extracted from alfalfa plant were identified using matrix-assisted laser desorption/ionization with time-offlight mass spectrometry (MALDI-TOF-MS); however, the technique is useful and sensitive for identification, but not suitable for quantification (Al-Suod et al 2018b).…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, gas chromatography–mass spectrometry122,123 in which some mono- and disaccharides are derivatized for quantification is used; other methods include high-performance anion-exchange chromatography with pulsed amperometric detection,124,125 capillary electrophoresis, among others.…”
Section: Analytic Methods To Determine Intestinal Permeabilitymentioning
confidence: 99%