2002
DOI: 10.1002/clc.4960251108
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of Mitral Regurgitation by the Proximal Flow Convergence Method—Comparison of Transthoracic and Transesophageal Echocardiography

Abstract: SummaryBackground: No data exist to indicate whether transthoracic (TTE) and transesophageal echocardiography (TEE) are of comparable value for the detection and quantification of mitral regurgitation using the proximal flow convergence method.Hypothesis: The study was performed to compare the value of TTE and TEE for the detection and quantification of mitral regurgitation using this method.Methods: The study included 57 patients with and 11 patients without mitral regurgitation. In all patients, the proximal… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2006
2006
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 28 publications
0
6
0
Order By: Relevance
“…The images of sufficient quality to visualize PISA radius can be obtained in 92-98% of patients [63]. The optimal Nyquist limit corresponds to ∼10% of maximal regurgitation velocity, or approximately 30-40 cm/sec [59,64,65] Setting the Nyquist limit too high, would force the operator to use a PISA hemisphere close to the regurgitant orifice and would increase the error in assessing the EROA [66].…”
Section: Effective Regurgitant Orifice Area By Pisamentioning
confidence: 99%
“…The images of sufficient quality to visualize PISA radius can be obtained in 92-98% of patients [63]. The optimal Nyquist limit corresponds to ∼10% of maximal regurgitation velocity, or approximately 30-40 cm/sec [59,64,65] Setting the Nyquist limit too high, would force the operator to use a PISA hemisphere close to the regurgitant orifice and would increase the error in assessing the EROA [66].…”
Section: Effective Regurgitant Orifice Area By Pisamentioning
confidence: 99%
“…Of the 44 included studies, there were 17 studies 62,69,72,74,75,77,79,80,82,86,90,91,95,97,[100][101][102] that included AF patients in the population. Of these, for two studies 79,91 all participants had AF.…”
Section: Quantity and Quality Of Research Availablementioning
confidence: 99%
“…they differed from level 2 only in being among non-consecutive patients. Twenty-two of the studies were level 3b, 62,69,71,72,[77][78][79]82,[85][86][87]89,90,92,93,95,96,98,100,101,104,105 comparisons with a reference standard that did not meet criteria for higher levels of evidence. There were four diagnostic case-control studies, level 3c.…”
Section: Quality Of Included Studiesmentioning
confidence: 99%
See 2 more Smart Citations