2022
DOI: 10.1142/s1793984422500064
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of Magnetic Nanoparticles in ex vivo Colorectal Lymph Nodes

Abstract: En-bloc tumor resection is the standard treatment for locally advanced colorectal cancer (CRC). An extensive histopathological assessment is necessary to evaluate the metastatic spread and adjuvant therapy. Sentinel lymph node biopsy decreases the histopathological burden when only sentinel lymph nodes (SLNs) are examined. This study aims to evaluate the spread of a magnetic tracer throughout the lymphatic system after ex vivo injection in en-bloc resected specimens of patients with CRC. To achieve this, lymph… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
1
1

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 20 publications
0
2
0
Order By: Relevance
“…The SLN (situated in a glass tube) was placed in an alternating magnetic field generated by an excitation coil to measure the dynamic magnetisation curve. The specific SPaQ settings used involve AC amplitude of 0.83 mT, AC frequency of 2.5 kHz and DC field strength of 4.99 mT [13]. The evaluation was supported by a lookup table (LUT) tailored to quantify the accumulation of the Magtrace magnetic tracer within LN through the utilisation of magnetic readout counts [14].…”
Section: Assessment Of Iron Content By Spaqmentioning
confidence: 99%
“…The SLN (situated in a glass tube) was placed in an alternating magnetic field generated by an excitation coil to measure the dynamic magnetisation curve. The specific SPaQ settings used involve AC amplitude of 0.83 mT, AC frequency of 2.5 kHz and DC field strength of 4.99 mT [13]. The evaluation was supported by a lookup table (LUT) tailored to quantify the accumulation of the Magtrace magnetic tracer within LN through the utilisation of magnetic readout counts [14].…”
Section: Assessment Of Iron Content By Spaqmentioning
confidence: 99%
“…The SLN (situated in a glass tube) was placed in an alternating magnetic eld generated by an excitation coil to measure the dynamic magnetisation curve. The speci c SPaQ settings used involve AC amplitude of 0.83 mT, AC frequency of 2.5 kHz and DC eld strength of 4.99 mT [13]. The evaluation was supported by a lookup table (LUT) tailored to quantify the accumulation of the Magtrace magnetic tracer within LN through the utilisation of magnetic readout counts [14].…”
Section: During the Surgerymentioning
confidence: 99%