2011
DOI: 10.1016/j.jchromb.2011.02.034
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of Alefacept, an immunosuppressive fusion protein in human plasma using a protein analogue internal standard, trypsin cleaved signature peptides and liquid chromatography tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
3
2
2

Relationship

2
5

Authors

Journals

citations
Cited by 25 publications
(14 citation statements)
references
References 38 publications
(49 reference statements)
0
14
0
Order By: Relevance
“…Partial protein precipitation, using organic solvents along with surfactants, is used as a simple sample purification technique to deplete the endogenous plasma proteins. Partial protein precipitation eliminates larger proteins but leave smaller ones in solution [11][12][13]. Protein precipitation could have low recovery due to losses as a result co-precipitation, which would be a drawback.…”
Section: Non-selective Protein Enrichment Techniquesmentioning
confidence: 99%
See 3 more Smart Citations
“…Partial protein precipitation, using organic solvents along with surfactants, is used as a simple sample purification technique to deplete the endogenous plasma proteins. Partial protein precipitation eliminates larger proteins but leave smaller ones in solution [11][12][13]. Protein precipitation could have low recovery due to losses as a result co-precipitation, which would be a drawback.…”
Section: Non-selective Protein Enrichment Techniquesmentioning
confidence: 99%
“…Halquist et al reported an LC-MS/MS method for quantification of Alefacept, a therapeutic protein for treatment of psoriasis, in human plasma using horse heart myoglobin a protein analogue internal standard [11]. The method used partial protein precipitation to selectively precipitate background proteins while retaining the analyte protein and the internal standard protein in solution.…”
Section: Analogue Proteins As Internal Standardsmentioning
confidence: 99%
See 2 more Smart Citations
“…Our previous successes with column trapping lead us to investigate 2D-LC for chromatographic separation of OXM. Initially, C18 guard columns were attempted as the loading column to provide a short loading time as demonstrated previously [36]. The mobile phase optimization study of 3-NBA described in Section 2.5 provided compelling evidence to continue use of the Waters XBridge BEH300 C18 for the analytical column.…”
Section: D-lc-ms/ms Using Reversed Phase Ion Pair Chromatographymentioning
confidence: 99%