1996
DOI: 10.1002/(sici)1099-0801(199607)10:4<161::aid-bmc579>3.0.co;2-3
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of 9-Carboxy-11-nor-Δ9-tetrahydrocannabinol in Urine Using Brominated 9-Carboxy-11-nor-Δ9-tetrahydrocannabinol as the Internal Standard and High-Performance Liquid Chromatography with Electrochemical Detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
1

Year Published

2000
2000
2016
2016

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(7 citation statements)
references
References 20 publications
0
6
1
Order By: Relevance
“…Various antioxidant agents are used to protect the degradation of DHPG throughout analysis [9,19,25,26]. Extraction with cation-exchange columns [27], boronate gels [21,27], C18 matrix [12,13,16,[28][29][30], MFC18 [29] and PLRP-S or OASIS HLB [13,30] have provided good recoveries of NE and other catecholamines from plasma and urine. However, recoveries of other catecholamines and metabolites, such as DHPG and 3,4-dihydroxylalanine (DOPA) in plasma, have not been reported using this method.…”
Section: Introductioncontrasting
confidence: 59%
See 2 more Smart Citations
“…Various antioxidant agents are used to protect the degradation of DHPG throughout analysis [9,19,25,26]. Extraction with cation-exchange columns [27], boronate gels [21,27], C18 matrix [12,13,16,[28][29][30], MFC18 [29] and PLRP-S or OASIS HLB [13,30] have provided good recoveries of NE and other catecholamines from plasma and urine. However, recoveries of other catecholamines and metabolites, such as DHPG and 3,4-dihydroxylalanine (DOPA) in plasma, have not been reported using this method.…”
Section: Introductioncontrasting
confidence: 59%
“…These retention times, caused by intermolecular forces, change depending on the concentration of DPB and the particles. The recovery of NE was greatly improved when the concentration of DPB was decreased to 0.01%, compared with previously reports of 0.1 or 0.2% [12,16,29,30]. This improvement might be partly due to C30 particle characteristics.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…THC has also been determined in human urine using a novel brominated 9-carboxy-11-nor-∆ 9 -tetrahydrocannabinol as an internal standard [41]. Amperometric determination was undertaken at +0.85 V (vs. Ag/AgCl) using gradient elution.…”
Section: Cannabinoidsmentioning
confidence: 99%
“…Various sensing methods for phenolic compounds are used, including electrochemical techniques, [4][5][6] high performance liquid chromatography, 1,[7][8][9] which is sometimes used in conjunction with electrochemical techniques, 1,7,8 and spectrophotometry. 10,11 Given their high reliability and their speed of response signicant recent research has focussed primarily on electrochemical sensors.…”
Section: Introductionmentioning
confidence: 99%