2016
DOI: 10.1259/bjr.20160652
|View full text |Cite
|
Sign up to set email alerts
|

Quality of tri-Co-60 MR-IGRT treatment plans in comparison with VMAT treatment plans for spine SABR

Abstract: FULL PAPERQuality of tri-Co-60 MR-IGRT treatment plans in comparison with VMAT treatment plans for spine SABR Objective: To investigate the plan quality of tri-Co-60 intensity-modulated radiation therapy (IMRT) plans for spine stereotactic ablative radiotherapy (SABR). Methods: A total of 20 patients with spine metastasis were retrospectively selected. For each patient, a tri-Co-60 IMRT plan and a volumetric-modulated arc therapy (VMAT) plan were generated. The spinal cords were defined based on MR images for … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
39
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 26 publications
(41 citation statements)
references
References 26 publications
0
39
0
Order By: Relevance
“…To minimize the target margin compensating for the respiratory motion, various respiratory‐gating techniques to account for the respiratory motion during beam delivery were investigated and clinically applied . Recently, the respiratory‐gating technique based on near‐real‐time magnetic resonance image (MRI) became available with the ViewRay™ system (ViewRay Inc., Cleveland, OH, USA) . The ViewRay system is capable of the near‐real‐time respiratory gated radiation therapy by continuous acquisition of sagittal planar MR images (a single cine image at 4 frames/s or three cine images at 2 frames/s) during treatment .…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations
“…To minimize the target margin compensating for the respiratory motion, various respiratory‐gating techniques to account for the respiratory motion during beam delivery were investigated and clinically applied . Recently, the respiratory‐gating technique based on near‐real‐time magnetic resonance image (MRI) became available with the ViewRay™ system (ViewRay Inc., Cleveland, OH, USA) . The ViewRay system is capable of the near‐real‐time respiratory gated radiation therapy by continuous acquisition of sagittal planar MR images (a single cine image at 4 frames/s or three cine images at 2 frames/s) during treatment .…”
Section: Introductionmentioning
confidence: 99%
“…In addition, the three Co‐60 are not always used simultaneously during treatment and the use of the Co‐60 source at a particular gantry angle is dependent on the treatment plan . Therefore, the comparable dose‐rate of the ViewRay system to the linac is not always consistently maintained, which results in longer treatment time than with the linac‐based IMRT or VMAT . The increase in the treatment time of the ViewRay system becomes severe when the respiratory‐gating technique is applied.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…[1][2][3][4][5][6][7][8] nology, MR imaging system can be installed in a radiation treatment system and then MR images can be obtained during radiation therapy, which is called MR-IGRT system. 2,[9][10][11] Recently, the most representative MR-IGRT system in the field of radiotherapy is the ViewRay ® system (ViewRay Inc., Cleveland, OH, USA) which consists in a MR scanner of 0.35 T static magnetic field for imaging and tri Co-60 sources for treatment. 1,[11][12][13] The total dose rate of the tri Co-60 sources is 550 cGy/min, which is ideal dose rate in radiotherapy planning system (RTP) and the tri Co-60 sources are positioned at 120-degree intervals in a ring type gantry.…”
Section: Introductionmentioning
confidence: 99%