Quality of the Air and Health Assessment of the Medical Staff Handling Disinfection Chemicals in Lithuanian Hospitals

Abstract: The use of chemical disinfectants where ventilation is insufficient can produce morbidity and allergic responses. Although disinfection is the universal tool for prevention of infections, the chemicals used can irritate the eyes and skin and may have neurotoxic and sensitising effects. The objective in the present study was to evaluate such chemical hazards, the use of personal protective equipment and the health status of those who handle disinfection chemicals in Lithuanian hospitals. Nine hospitals in Vilni… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
4
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 13 publications
(17 reference statements)
0
4
1
Order By: Relevance
“…In our study, the disinfection room is equipped with a general ventilation system delivering a high air flowrate (1,170 m 3 /h). Glumbakaite et al [5] reported much higher concentrations of alcohols than those measured in our study. The authors measured concentrations of alcohols before, during and after disinfection with alcohols, while in our study alcohol-based products were not used for disinfection of medical devices.…”
Section: Discussioncontrasting
confidence: 66%
See 4 more Smart Citations
“…In our study, the disinfection room is equipped with a general ventilation system delivering a high air flowrate (1,170 m 3 /h). Glumbakaite et al [5] reported much higher concentrations of alcohols than those measured in our study. The authors measured concentrations of alcohols before, during and after disinfection with alcohols, while in our study alcohol-based products were not used for disinfection of medical devices.…”
Section: Discussioncontrasting
confidence: 66%
“…Most of the previous works have measured VOCs concentrations in disinfection rooms where medical devices are disinfecting and sterilizing with glutaraldehyde or formaldehyde. Concentrations of glutaraldehyde were widely variable between studies [6], [5], [43], [44], The difference being probably due to the type of ventilation. The highest concentrations were observed in rooms with natural ventilation [5].…”
Section: Discussionmentioning
confidence: 94%
See 3 more Smart Citations