2009
DOI: 10.1007/s11947-009-0281-0
|View full text |Cite
|
Sign up to set email alerts
|

Quality Evaluation of an Ohmically Cooked Ham Product

Abstract: Selected parameters (cooking loss, instrumental colour and texture and sensory quality) of a brine-injected pork muscle cooked by a novel and rapid ohmic cooking protocol were examined and compared with those obtained in conventionally cooked samples. Ohmic samples were cooked using either a low-temperature long-time (LTLT) protocol (2 min equilibration, 5 min ohmic heating to 70°C, 8 min holding) or a high-temperature short-time (HTST) procedure (2 min equilibration, 6 min ohmic heating to 95°C) performed wit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
2
0
1

Year Published

2011
2011
2019
2019

Publication Types

Select...
3
3
1

Relationship

1
6

Authors

Journals

citations
Cited by 19 publications
(4 citation statements)
references
References 21 publications
1
2
0
1
Order By: Relevance
“…The moisture content is in agreement with other works from literature that studied cooked ham composition (Moretti et al 2009;Tomović et al 2013). Similar values were also observed for total protein (Zell et al 2012), fat (Válková et al 2007) and ash content (Casiraghi et al 2007).…”
Section: Chemical Characteristics Of Cooked Hamsupporting
confidence: 91%
See 1 more Smart Citation
“…The moisture content is in agreement with other works from literature that studied cooked ham composition (Moretti et al 2009;Tomović et al 2013). Similar values were also observed for total protein (Zell et al 2012), fat (Válková et al 2007) and ash content (Casiraghi et al 2007).…”
Section: Chemical Characteristics Of Cooked Hamsupporting
confidence: 91%
“…Similar values were also observed for total protein (Zell et al . ), fat (Válková et al . ) and ash content (Casiraghi et al .…”
Section: Resultsmentioning
confidence: 99%
“…Ohmik ısıtma yöntemiyle homojen bir sıcaklık dağılımı elde edildiği için geleneksel ısıtma yöntemine göre daha kısa pişirme süresi sağladığı gözlemlenmiştir. Zell vd., 2012 jambon örneklerinde ohmik ısıtma (LTLT-70 ˚C, 5 dk/ HTST-95 ˚C, 6 dk) ve geleneksel ısıtma (80˚C, 120 dk) yöntemlerini pişirme kaybı, renk, doku ve duyusal kalite açısından incelemiştir [40]. LTLT uygulamasının diğer uygulamalara kıyasla çok daha düşük pişirme kaybı verdiği belirtilmiştir.…”
Section: Ohmik Isıtmaunclassified
“…A patent was granted but the difficulties in maintaining stable operating conditions over prolonged periods ultimately led to this method being abandoned. In the past number of years a number of more in depth studies have been conducted on ohmic cooking of meat and meat products (De Halleux et al, 2005;Piette et al, 2000aPiette et al, ,b, 2001Piette et al, , 2004Shirsat et al, 2004a,d;Zell et al, 2009a,c;,b, 2011, 2012. According to Piette and Brodeur (2003) this group developed a batch procedure for cooking 2 kg batches of liver pate and hams in 10 min, but the subsequent development of a prototype continuous method yielded disappointing results.…”
Section: Introductionmentioning
confidence: 99%