Quality control of CT systems by automated monitoring of key performance indicators: a two‐year study

Abstract: The purpose of this study was to develop a method of performing routine periodical quality controls (QC) of CT systems by automatically analyzing key performance indicators (KPIs), obtainable from images of manufacturers' quality assurance (QA) phantoms. A KPI pertains to a measurable or determinable QC parameter that is influenced by other underlying fundamental QC parameters. The established KPIs are based on relationships between existing QC parameters used in the annual testing program of CT scanners at th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
33
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 38 publications
(33 citation statements)
references
References 9 publications
0
33
0
Order By: Relevance
“…Several QC phantoms are available for image quality testing of CT scanners, ranging from vendor specific phantoms to widely used commercial phantoms like Catphan (The Phantom Laboratory, Salem NY, USA) 3, 4, 5, 6, 7. Publications by international organizations like the International Electrotechnical Commission (IEC) and Institute of Physics and Engineering in Medicine (IPEM) provide specific recommendations related to test methods, test frequencies, and tolerance levels for different QC tests in CT 8, 9, 10.…”
Section: Introductionmentioning
confidence: 99%
See 4 more Smart Citations
“…Several QC phantoms are available for image quality testing of CT scanners, ranging from vendor specific phantoms to widely used commercial phantoms like Catphan (The Phantom Laboratory, Salem NY, USA) 3, 4, 5, 6, 7. Publications by international organizations like the International Electrotechnical Commission (IEC) and Institute of Physics and Engineering in Medicine (IPEM) provide specific recommendations related to test methods, test frequencies, and tolerance levels for different QC tests in CT 8, 9, 10.…”
Section: Introductionmentioning
confidence: 99%
“…Tolerance levels should be wide enough so that only serious drifting or sudden errors are detected and not clinically irrelevant daily fluctuations. The recommended test frequency should aim to balance between being frequent enough to ensure adequate image quality, while infrequent enough to reduce time spent by the staff and avoid unnecessary interference with clinical work 6, 7…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations