Quality-by-design model in optimization of PEG-PLGA nano micelles for targeted cancer therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 18 publications
(7 citation statements)
references
References 40 publications
0
7
0
Order By: Relevance
“…Default setting on the Zetasizer was used, including refractive index and absorption, the dispersant used was water and measurement angle was 173. Measurements were repeated 5 times, 3 min each and data were analysed by intensity distribution …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Default setting on the Zetasizer was used, including refractive index and absorption, the dispersant used was water and measurement angle was 173. Measurements were repeated 5 times, 3 min each and data were analysed by intensity distribution …”
Section: Methodsmentioning
confidence: 99%
“…Measurements were repeated 5 times, 3 min each and data were analysed by intensity distribution. [19] Determination of optimized nano-esculetin formulation Increasing amounts of esculetin (10-25 mg) were successively uploaded to 50 mg of PLGA (in 20 ml) using abovementioned method, and PS was measured. Excess amounts of esculetin outpouring from PLGA micelles caused disruption in the mono-dispersity of particles.…”
Section: Determination Of Particle Size (Ps)mentioning
confidence: 99%
“…The subsequent mathematical treatment enables the optimization of experimental conditions to get the desired result and also indicates which parameters lead to synergistic or antagonist effects. This approach has been regularly used for the formulation of lipidic vectors [153] and is also increasingly assessed for polymeric systems [154][155][156][157]. To our knowledge, only two examples have performed DOE for PDT vectors.…”
Section: Ps Positioningmentioning
confidence: 99%
“…Measurements were performed five times, three minutes each and the data was analyzed in terms of number, intensity and volume distribution. Although, the "average size" presented by Zetasizer was used in QbD calculations (Eskandari et al, 2018). Laser Doppler micro-electrophoresis method using a folded capillary zeta cell (Malvern Instruments Ltd) was used to measure ZP.…”
Section: Determination Of Ps Poly Dispersity Index (Pdi) and Zpmentioning
confidence: 99%