2018
DOI: 10.1007/978-1-4939-7592-1_27
|View full text |Cite
|
Sign up to set email alerts
|

Quality-Assured Biobanking: The Leiden University Medical Center Model

Abstract: Prospective or "de novo" biobanking is becoming increasingly popular. Biobanks are installed to provide large collections of biological materials for future medical research. Quality assurance of biobank samples is an important aspect of biobanking. Therefore, it is vital that all samples are collected and processed in a similar manner according to standardized procedures to ensure high-quality samples and reduce variability in the analytical process. We describe the processes of the centralized biobanking fac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 12 publications
0
7
0
Order By: Relevance
“…A total of 500 μL serum is stored at −20°C immediately after processing and transferred to −80°C freezers within maximally 8 hours after collection. ( 23 ) Serum levels of cytokines were analyzed using electrochemiluminescent immunoassays from Meso Scale Discovery, Rockville, MD, USA; IL‐1β, IL‐6, IL‐8, TNF‐α, IL‐10, IFN‐γ, IL‐12p70, IL‐13, IL‐2, and IL‐4 with V‐Plex Proinflammatory panel 1 (K15049D‐1) and IL‐17A, IL‐21, IL‐22, IL‐23, IL‐27, IL‐31, and macrophage inflammatory protein‐3 alpha (MIP‐3α) with using V‐Plex Plus Th17 Panel 1 Human Kit (K15085G‐1). All analyses were conducted according to the manufacturer's recommendations and without additional freeze/thaw cycles and with the eight‐point calibration curve, providing a dynamic range, analyzed in duplicate.…”
Section: Methodsmentioning
confidence: 99%
“…A total of 500 μL serum is stored at −20°C immediately after processing and transferred to −80°C freezers within maximally 8 hours after collection. ( 23 ) Serum levels of cytokines were analyzed using electrochemiluminescent immunoassays from Meso Scale Discovery, Rockville, MD, USA; IL‐1β, IL‐6, IL‐8, TNF‐α, IL‐10, IFN‐γ, IL‐12p70, IL‐13, IL‐2, and IL‐4 with V‐Plex Proinflammatory panel 1 (K15049D‐1) and IL‐17A, IL‐21, IL‐22, IL‐23, IL‐27, IL‐31, and macrophage inflammatory protein‐3 alpha (MIP‐3α) with using V‐Plex Plus Th17 Panel 1 Human Kit (K15085G‐1). All analyses were conducted according to the manufacturer's recommendations and without additional freeze/thaw cycles and with the eight‐point calibration curve, providing a dynamic range, analyzed in duplicate.…”
Section: Methodsmentioning
confidence: 99%
“…In this cohort study 96 serum samples were collected from a IRB approved biobank [20]. All samples were retrieved from patients ≥18 years of age who visited the outpatient clinic of the Center for Bone Quality, Department of Endocrinology of the Leiden University Medical Center in the Netherlands between 2015 and 2021 and retrieved a definitive diagnosis of any subtype of FD/MAS.…”
Section: Subjectsmentioning
confidence: 99%
“…All samples were retrieved from patients ≥18 years of age who visited the outpatient clinic of the Center for Bone Quality, Department of Endocrinology of the Leiden University Medical Center in the Netherlands between 2015 and 2021 and retrieved a definitive diagnosis of any subtype of FD/MAS. All samples were taken before the afternoon with a maximum processing time of 4 hours [20]. This study was approved by the Medical Ethics Committee and scientific biobank committee [20].…”
Section: Subjectsmentioning
confidence: 99%
“…Standardized strategies and best practice protocols for blood collection and manipulation have been proposed to reduce pre-analytical variables [16][17][18]. International standard ISO 15189, which specifies requirements for quality and competence in medical laboratories, contains several sections focused on the pre-analytical phase [19].…”
Section: Introductionmentioning
confidence: 99%