2011
DOI: 10.1117/1.3595424
|View full text |Cite
|
Sign up to set email alerts
|

Qualitative near-infrared vascular imaging system with tuned aperture computed tomography

Abstract: Abstract. We developed a novel system for imaging and qualitatively analyzing the surface vessels using nearinfrared (NIR) radiation using tuned aperture computed tomography (TACT R ). The system consisted of a NIRsensitive CCD camera surrounded by sixty light emitting diodes (with wavelengths alternating between 700 or 810 nm). This system produced thin NIR tomograms, under 0.5 mm in slice thickness. The venous oxygenation index reflecting oxygen saturation levels calculated from NIR tomograms was more sensit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2013
2013
2015
2015

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 23 publications
0
3
0
Order By: Relevance
“…The challenge of using NIR is penetration depth; low-quality images are generated for deep veins. 20 We consider that our investigated veins were deep and, therefore, difficult to visualize with AccuVein. In this study, we did not detect a significant difference in the depth of the veins visualized by the two devices.…”
Section: Discussionmentioning
confidence: 99%
“…The challenge of using NIR is penetration depth; low-quality images are generated for deep veins. 20 We consider that our investigated veins were deep and, therefore, difficult to visualize with AccuVein. In this study, we did not detect a significant difference in the depth of the veins visualized by the two devices.…”
Section: Discussionmentioning
confidence: 99%
“…[1][2][3][4][5][6][7][8][9][10][11][12][13][14][15] These studies use only spatial information of the measured NIR images in order to improve detection and localization of blood vessels and estimate useful anatomical information clinically. However, there has been no study that has focused on extracting both the spatial and temporal features of dynamic NIR images obtained via non-contact near-infrared optical scanner (NIROS) without the use of external contrast agents.…”
Section: Introductionmentioning
confidence: 99%
“…CCD or CMOS camera) for non-contact imaging. The various fiberfree non-contact NIR imagers available to date are provided in Table 1 [8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27]. These imagers employ either reflectance or transmittance mode to image tissue phantoms, blood vessels, and/or veins of the skin surface.…”
Section: Introductionmentioning
confidence: 99%