Quadriceps tendon allografts as an alternative to Achilles tendon allografts: a biomechanical comparison

Abstract: Quadriceps tendon with a patellar bone block may be a viable alternative to Achilles tendon for anterior cruciate ligament reconstruction (ACL-R) if it is, at a minimum, a biomechanically equivalent graft. The objective of this study was to directly compare the biomechanical properties of quadriceps tendon and Achilles tendon allografts. Quadriceps and Achilles tendon pairs from nine research-consented donors were tested. All specimens were processed to reduce bioburden and terminally sterilized by gamma irrad… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

6
39
2
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(48 citation statements)
references
References 26 publications
6
39
2
1
Order By: Relevance
“…Moreover, the ha-PLGA fleeces, different from the rd-PLGA ones used as control, closely mimic the biomechanical properties of a native tendon, as in fact, especially the stress values were comparable to those of the human tissues (i.e., human Achilles, rotator, and patellar tendons) [2]. In detail, the stress values of the produced ha-PLGA fleeces (26.02 ± 1.75 MPa) closely resembled those published for human Achilles tendons [2,65], human patellar tendons (5-65 MPa) [2,66], human rotator tendons (14-45 MPa), and human Achilles grafts (16 MPa) [2]. These obtained data are in accordance with those published previously and confirm that the mechanical properties depend on the fiber orientation and possess higher mechanical strength when the fibers are aligned, compared to the randomly distributed ones [16,56,67].…”
Section: Discussionsupporting
confidence: 66%
“…Moreover, the ha-PLGA fleeces, different from the rd-PLGA ones used as control, closely mimic the biomechanical properties of a native tendon, as in fact, especially the stress values were comparable to those of the human tissues (i.e., human Achilles, rotator, and patellar tendons) [2]. In detail, the stress values of the produced ha-PLGA fleeces (26.02 ± 1.75 MPa) closely resembled those published for human Achilles tendons [2,65], human patellar tendons (5-65 MPa) [2,66], human rotator tendons (14-45 MPa), and human Achilles grafts (16 MPa) [2]. These obtained data are in accordance with those published previously and confirm that the mechanical properties depend on the fiber orientation and possess higher mechanical strength when the fibers are aligned, compared to the randomly distributed ones [16,56,67].…”
Section: Discussionsupporting
confidence: 66%
“…The current study calculated creep as the percent difference in graft elongation due to creep, whereas previous studies calculated creep as the difference in graft strain between first and last cycles [24,36]. Thus, direct comparisons cannot be made between studies.…”
Section: Discussionmentioning
confidence: 87%
“…Full-thickness quadriceps tendon grafts of approximate dimensions of 1 by 10 cm [24,35,36] were prepared with attached bone block by an orthopaedic surgeon to mimic grafts for anatomic doublebundle ACL reconstruction surgery [7,17,19,37]. Each graft was then split in half using a No.…”
Section: Methodsmentioning
confidence: 99%
“…Tensile tests using tensile testing system MTS 810 (MTS Systems Corporation, USA) were performed on 10 specimens at room temperature (25°C), a load speed of 0.1 mm/s, and a gauge length of 100 mm while gradually increasing the load until the occurrence of fractures (Figure ). In the current study, we have measured strain from the change in the grip‐to‐grip length relative to the initial grip‐to‐grip length . The stress‐strain curves obtained were used to measure the tensile strength, yield strength, and elongation of the copper tubes.…”
Section: Mechanical Tests On Copper Tubesmentioning
confidence: 99%