2012
DOI: 10.1111/j.1469-0691.2012.03992.x
|View full text |Cite
|
Sign up to set email alerts
|

Q fever endocarditis associated with a cardiovascular implantable electronic device

Abstract: Clin Microbiol Infect 2012; 18: E482–E484 Abstract Cardiovascular implantable electronic devices (CIEDs) are frequently related to endocarditis. Most cases of intravascular CIED infections are usually related to skin flora, but a few cases may occur with negative blood culture. Coxiella burnetii is one of the main causes of blood culture‐negative endocarditis in native and prosthetic valves, but to date no cases related to CIED have been published. Herein we report two cases of Q fever endocarditis related to … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 14 publications
0
8
0
Order By: Relevance
“…Regarding more severe valvulopathy, aortic regurgitation is at higher risk than mitral regurgitation and aortic stenosis (320). Also, three cases of C. burnetii infection of cardiovascular implantable electronic devices and a single case of C. burnetii infection of an intracardiac thrombus mimicking atrial myxoma have been reported to date (412,542,543).…”
Section: Clinical Manifestationsmentioning
confidence: 99%
“…Regarding more severe valvulopathy, aortic regurgitation is at higher risk than mitral regurgitation and aortic stenosis (320). Also, three cases of C. burnetii infection of cardiovascular implantable electronic devices and a single case of C. burnetii infection of an intracardiac thrombus mimicking atrial myxoma have been reported to date (412,542,543).…”
Section: Clinical Manifestationsmentioning
confidence: 99%
“…faecalis and H . parainfluenzae , respectively.For all these 24 patients, NGS results allowed us to retrospectively confirm the previous diagnosis.In addition, the 16S-NGS test data assessment, led us to corroborate mixed infections within the clinical and epidemiologic context when considering relatively low abundant microorganisms.Thus, for patient ID #1649, whose initial microbiologic diagnosis included Brucella melitensis (by BC and PCR) and Coxiella burnetii (by indirect immunofluorescence assays and specific PCR) (24), metagenomic results showed Brucellaceae as the most relative abundant taxa (99.7%) and, interestingly, C . burnetii was also detected at low relative abundance (<1%).For patient ID #1990, conventional methods (BC and PCR) led to an IE diagnosis due to E .…”
Section: Resultsmentioning
confidence: 99%
“…In an attempt to secure a microbial diagnosis of CIED‐IE cases, an extensive evaluation, including serologic and antigen assays, similar to those recommended for CN endocarditis, was performed for five patients in our study cohort and was negative in all five. While there are published case reports of Brucella ‐ and Coxiella ‐related CIED infection, these organisms are extremely rare causes of device infection and should only be considered in patients with associated risk factors and relevant exposure history.…”
Section: Discussionmentioning
confidence: 99%