1992
DOI: 10.1038/358287b0
|View full text |Cite
|
Sign up to set email alerts
|

Pyroelectric X-ray generator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
74
0
1

Year Published

2001
2001
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 141 publications
(77 citation statements)
references
References 3 publications
2
74
0
1
Order By: Relevance
“…In order to produce higher energy beams the crystal was heated from the + z base to 160 0 C and allowed to cool to room temperature at <10 mtorr. It produced maximum energy electron beams of up to 145 keV when the temperature was ~30 0 C. That the electron beam energy was at least 80 keV (Au K edge) for a significant time was confirmed by irradiating gold and observing the K X-rays 2,3 .…”
Section: Discussionmentioning
confidence: 94%
See 1 more Smart Citation
“…In order to produce higher energy beams the crystal was heated from the + z base to 160 0 C and allowed to cool to room temperature at <10 mtorr. It produced maximum energy electron beams of up to 145 keV when the temperature was ~30 0 C. That the electron beam energy was at least 80 keV (Au K edge) for a significant time was confirmed by irradiating gold and observing the K X-rays 2,3 .…”
Section: Discussionmentioning
confidence: 94%
“…Although some of the remarkable electrical properties of pyroelectric crystals have been known since ancient Greek times 1 , surprising new effects and practical applications are constantly being discovered [1][2][3][4][5][6] . There is a voluminous literature on electron emission by pyroelectric crystals.…”
Section: Introductionmentioning
confidence: 99%
“…DOI: 10.21883/PJTF.2018.02. 45460.16978 Малогабаритный пироэлектрический ускоритель был предложен в [1], его свойства исследовались несколькими группами (см., напри-мер, работы [2,3] и ссылки в них). В этих работах использовались пироэлектрические кристаллы, такие как ниобат лития (LiNbO 3 ) или танталат лития (LiTaO 3 ).…”
Section: поступило в редакцию 19 июля 2017 гunclassified
“…[1][2][3][4] Recently, a novel and portable X-ray emitter using the charging phenomena of a pyroelectric crystal has become commercially available; its size is 15 mm in diameter and 10 mm in height. With a controller box that works off a 9 V dry electric battery, the full dimensions of this device are only 125 mm in length, 45 mm in width and 30 mm in height.…”
mentioning
confidence: 99%