1980
DOI: 10.1021/j100439a007
|View full text |Cite
|
Sign up to set email alerts
|

Pycnometric vs. densimetric measurements of highly viscous protein solutions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
27
0

Year Published

1982
1982
2014
2014

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 55 publications
(29 citation statements)
references
References 3 publications
2
27
0
Order By: Relevance
“…Several researchers [9,10,[45][46][47][48][49][50][51] have analyzed, mainly at atmospheric pressure, how density measurements through mechanical oscillator densimeters are affected by the sample viscosity, and it is thus necessary to apply a correction factor to experimental data. From their results, it is concluded that the correction factor depends not only on the sample viscosity but also on the specific design of the oscillator tube.…”
Section: Evaluation Of the Experimental Density Uncertaintymentioning
confidence: 99%
“…Several researchers [9,10,[45][46][47][48][49][50][51] have analyzed, mainly at atmospheric pressure, how density measurements through mechanical oscillator densimeters are affected by the sample viscosity, and it is thus necessary to apply a correction factor to experimental data. From their results, it is concluded that the correction factor depends not only on the sample viscosity but also on the specific design of the oscillator tube.…”
Section: Evaluation Of the Experimental Density Uncertaintymentioning
confidence: 99%
“…In this work, these parameters A(T) and B(T, p) were determined through the measurement of the oscillation period of a reference fluid and of the evacuated tube over all the experimental range, following the method developed An important feature concerning mechanical oscillator densimeters is the effect of the sample viscosity on the density measurements. The correction factor depends not only on the sample viscosity but also on the specific design of the oscillator tube [29,30]. For the DMA HPM model, Segovia et al [12] have obtained very recently, from data provided by Anton Paar, the following correlation equation:…”
Section: Apparatus and Proceduresmentioning
confidence: 99%
“…Several studies of this effect [11][12][13][14][15][16][17][18][19] have shown that the shape of the deviation is similar for all the studied vibrating-tube densimeters from Anton Paar. However, the reasons for this do not seem to be well understood.…”
Section: Introductionmentioning
confidence: 96%
“…The effect of viscosity on the density measurements made by U-tube densimeters has been extensively studied experimentally [11][12][13][14][15][16][17][18][19] and, recently, the increasing interest in high viscosity liquids has intensified the awareness in this effect [15][16][17][18]. However, to the knowledge of the authors, no theoretical study has been published.…”
Section: Introductionmentioning
confidence: 99%