2012
DOI: 10.1109/tpel.2011.2163826
|View full text |Cite
|
Sign up to set email alerts
|

PWM Plus Phase Angle Shift (PPAS) Control Scheme for Combined Multiport DC/DC Converters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
59
0
4

Year Published

2013
2013
2024
2024

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 120 publications
(63 citation statements)
references
References 27 publications
0
59
0
4
Order By: Relevance
“…When the switch of the boost converter is open, a large current flows through the power components, and therefore, power components with high current stress are required, absence of energy supply from the PV modules, the battery can provide energy to the DC bus. The three-port DC/DC converter can operate in different modes, thereby reducing the cost and size of the system [26][27][28][29][30][31][32][33]. However, it has a larger size, higher cost, and lower efficiency compared with the converter proposed in the current study.…”
Section: Introductionmentioning
confidence: 93%
“…When the switch of the boost converter is open, a large current flows through the power components, and therefore, power components with high current stress are required, absence of energy supply from the PV modules, the battery can provide energy to the DC bus. The three-port DC/DC converter can operate in different modes, thereby reducing the cost and size of the system [26][27][28][29][30][31][32][33]. However, it has a larger size, higher cost, and lower efficiency compared with the converter proposed in the current study.…”
Section: Introductionmentioning
confidence: 93%
“…For the dc-inductor based topology, the root mean square (rms) current of the low voltage side switches can be calculated as in (12). ;…”
Section: Dtmentioning
confidence: 99%
“…Even though the switch output capacitance is not considered in (21), as explained in [12], the larger the output capacitance, the longer the critical dead time leading to a reduced ZVS range.…”
Section: Dtmentioning
confidence: 99%
“…The ac inductor, L ac , is the power interface element between the two inputs and the output port. In order to decouple the two power inputs as well as to effectively regulate the output voltage, a duty cycle plus phase-shift control strategy [13], [14] is adopted. The duty cycle of the primary side switches is used to control the power flow between the two independent sources, i.e.…”
Section: Introductionmentioning
confidence: 99%