Push/Pull Hemodiafiltration: Technical Aspects and Clinical Effectiveness

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
18
0

Year Published

1999
1999
2015
2015

Publication Types

Select...
5
3

Relationship

2
6

Authors

Journals

citations
Cited by 15 publications
(18 citation statements)
references
References 11 publications
0
18
0
Order By: Relevance
“…Dual-stage HDF using dialyzers in series also enhances the total amount of ultrafiltration, but no replacement fluid infusion is required because continuous filtration at the upstream dialyzer, which exceeds the desired weight loss, is compensated for by backfiltration at the downstream dialyzer [7][8][9] . A similar but simpler method, the so-called push/pull HDF method which relies on repeated cycles of ultrafiltration and backfiltration [10][11][12][13][14][15] , was introduced to increase convective mass transfer, but this system requires an additional device, i.e. a double compartment piston pump, to regulate instantaneous blood and dialysate pressures [16] .…”
Section: Discussionmentioning
confidence: 99%
“…Dual-stage HDF using dialyzers in series also enhances the total amount of ultrafiltration, but no replacement fluid infusion is required because continuous filtration at the upstream dialyzer, which exceeds the desired weight loss, is compensated for by backfiltration at the downstream dialyzer [7][8][9] . A similar but simpler method, the so-called push/pull HDF method which relies on repeated cycles of ultrafiltration and backfiltration [10][11][12][13][14][15] , was introduced to increase convective mass transfer, but this system requires an additional device, i.e. a double compartment piston pump, to regulate instantaneous blood and dialysate pressures [16] .…”
Section: Discussionmentioning
confidence: 99%
“…The patients were treated with 4-hour hemodialysis using a pyrogen-free bicarbonate dialysate prepared according to a method reported elsewhere [38, 39]. During the study period, the predialysis endotoxin level in dialysate was confirmed to be undetectable by means of a Limulus amebocyte lysate assay (Endotoxin Wako; Wako Pure Chemical Industries, Osaka, Japan) [40].…”
Section: Methodsmentioning
confidence: 99%
“…This study was conducted in a prospective crossover fashion to reduce the individual variability, and the patients were treated using a pyrogen-free bicarbonate dialysate prepared according to a method reported elsewhere [38, 39]. During the study period, the endotoxin level in dialysate was confirmed to be undetectable by means of Limulus amebocyte lysate assay [40].…”
Section: Introductionmentioning
confidence: 99%
“…68 The PP HDF unit tends to relieve symptoms such as arthralgia (joint pain), irritability, pruritus, and insomnia more rapidly than conventional HD mode. [69][70][71] Furthermore, the optimal maintenance of membrane permeabilities by prompt BF has the added benefit of considerably inhibiting albumin loss in addition to increasing convection and diffusion. 72 During PP HDF, backward flushing of dialysate takes place within the time frame required for the protein layer to fully develop, and thus, it can effectively wash out the inner lumen and inhibit excessive albumin leakage.…”
Section: Push/pull Techniquesmentioning
confidence: 99%