2011
DOI: 10.2116/bunsekikagaku.60.877
|View full text |Cite
|
Sign up to set email alerts
|

Purity Evaluation of Alkylphenol Primary Standards Based on Japan Calibration Service System by Subtraction Method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
4

Relationship

3
1

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 7 publications
0
4
0
Order By: Relevance
“…The mass balance method on alkylphenols was separately applied to techniques based on GC-FID/KFT/VE and based on HPLC-DAD/KFT/VE to validate obtained values. A reliability of applied mass balance method was confirmed in comparison with data from the mass balance method mentioned above and from the freezing point depression method on NP, HP, and DCP which were amenable to DSC [25]. By determining x CRM,kg , the appropriate management of the JCSS under ensuring the traceability to the NMIJ CRMs is feasible, though x CRM,kg was not traceable to the SI.…”
Section: Overview Of Certificationmentioning
confidence: 84%
“…The mass balance method on alkylphenols was separately applied to techniques based on GC-FID/KFT/VE and based on HPLC-DAD/KFT/VE to validate obtained values. A reliability of applied mass balance method was confirmed in comparison with data from the mass balance method mentioned above and from the freezing point depression method on NP, HP, and DCP which were amenable to DSC [25]. By determining x CRM,kg , the appropriate management of the JCSS under ensuring the traceability to the NMIJ CRMs is feasible, though x CRM,kg was not traceable to the SI.…”
Section: Overview Of Certificationmentioning
confidence: 84%
“…For most of metals (elements) and gases, it is the only practical measure for purity assessment. The method is also commonly used to assess purity of organic materials [15][16][17][18][19][20]. The 'purity' of commercial reagents expressed as 'GC%' or 'LC%' is given by a simple version of this approach.…”
Section: Mass Balance Approachmentioning
confidence: 99%
“…From the results of the purity assay by the freezing point depression method using continuous scan mode, [14][15][16][17] the impurity concentration was obtained to ca. 0.1 mmol mol -1 , and the value was simultaneously consistent with the degree of freezing point depression.…”
Section: Assay For Purity Of Water Used For Certificationmentioning
confidence: 99%
“…Therefore, the impurity concentration detected by DSC was considered to be 0, and its uncertainty was considered to be 0.29 mmol mol -1 , which was estimated from the rectangular distribution of 0.999 -1.000 mol mol -1 . 16 From the results of the purity assay by the subtracting method, the residue after evaporation was less than the detection limit (10 μg g -1 ). Furthermore, the dissolved gases are assumed to have achieved equilibrium with the atmosphere; in accordance with the reported values of the contents of dissolved nitrogen, oxygen, and carbon dioxide at 20 and 30 C, the purity value and its uncertainty were estimated from the rectangular distribution between the two temperatures (23.8 ± 1.0 μg g -1 ).…”
Section: Assay For Purity Of Water Used For Certificationmentioning
confidence: 99%