2004
DOI: 10.1016/j.chemosphere.2003.09.014
|View full text |Cite
|
Sign up to set email alerts
|

Purification of triolein for use in semipermeable membrane devices (SPMDs)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0
1

Year Published

2004
2004
2014
2014

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 29 publications
(13 citation statements)
references
References 15 publications
0
12
0
1
Order By: Relevance
“…β-Carotene was used as such, while triolein was purified by washing cycles with pure MeOH and freezing/partial crystallization of the mixture at T < −20 °C, followed by a phase separation, until the measured absorbance of triolein was equal to that of the previous washing cycle (minimum four cycles). 24 Lutein and zeaxanthin were obtained through HPLC semipreparative isolation/purification of methanol extracts of maize flour. The mobile phase was methanol.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
“…β-Carotene was used as such, while triolein was purified by washing cycles with pure MeOH and freezing/partial crystallization of the mixture at T < −20 °C, followed by a phase separation, until the measured absorbance of triolein was equal to that of the previous washing cycle (minimum four cycles). 24 Lutein and zeaxanthin were obtained through HPLC semipreparative isolation/purification of methanol extracts of maize flour. The mobile phase was methanol.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
“…The SPMDs used in this project consisted of 97‐cm‐long (86 cm between the lipid‐containment seals) by 2.5‐cm‐wide layflat LDPE tubing containing 1.0 mL of purified triolein (Huckins et al, 2006; Lebo et al, 2004). The membrane surface area to total SPMD volume ratio of SPMDs used in this study was ≈86 cm 2 /mL, and triolein represented ≈20% of the mass of the SPMDs conforming to a “standard SPMD” as defined by Huckins et al (2006) Five SPMDs were placed in each deployment canister.…”
Section: Methodsmentioning
confidence: 99%
“…The SPMDs used in this project consisted of 97 cm long (86 cm between the lipid-containment seals) by 2.5 cm wide, lay-flat, low-density polyethylene tubing containing 1.0 ml of purified triolein [17]. The membrane surface area to total SPMD volume ratio of SPMDs used in the present study was approximately 86 cm 2 /ml, and triolein represented approximately 20% of the mass of the SPMDs, conforming to a standard SPMD as defined by Huckins et al [7].…”
Section: Passive Sampler Constructionmentioning
confidence: 99%