2004
DOI: 10.1016/j.pep.2003.09.006
|View full text |Cite
|
Sign up to set email alerts
|

Purification of human haptoglobin 1-1, 2-1, and 2-2 using monoclonal antibody affinity chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
41
0

Year Published

2004
2004
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(42 citation statements)
references
References 27 publications
1
41
0
Order By: Relevance
“…The plasma of each Hp phenotype was purified using chromatography on a mAb-based affinity column followed by a high-performance liquate chromatography procedure [16]. The plasma sample (2 mL) was added into the antibody affinity column.…”
Section: Methodsmentioning
confidence: 99%
“…The plasma of each Hp phenotype was purified using chromatography on a mAb-based affinity column followed by a high-performance liquate chromatography procedure [16]. The plasma sample (2 mL) was added into the antibody affinity column.…”
Section: Methodsmentioning
confidence: 99%
“…After SDS-and native-PAGE, gels were transferred to PVDF membranes according to a standard procedure as previously described [15]. After the transfer process, PVDF membranes were blocked with blocking buffer containing 5 % skimmed milk (w/v), 0.1 % Tween 20 in PBS (pH 7.4) for 1 h at room temperature.…”
Section: Western Blottingmentioning
confidence: 99%
“…Three phenotypes (Hp1-1, Hp2-2 and Hp2-1) of Hp have been identified in humans. It has been reported that the Hp phenotype identified in rats is similar to Hp1-1 phenotype in human and had a heterotetrameric (α2β2) structure [10]. The structural and functional differences between Hp phenotypes in humans have important biological and clinical consequences.…”
Section: Introductionmentioning
confidence: 97%
“…We therefore used a previously described HPLC-based size-exclusion chromatography procedure [24] for the isolation of deer Hp. However, this procedure is only suitable for isolating the Hps with a homogeneous structure, and is not suitable for human Hp 2-2 or 2-1 [22]. One minor disadvantage of the method was the contamination of the isolated Hp by a trace amount of hemoglobin (Fig.…”
Section: Isolation Of Deer Native Hpmentioning
confidence: 99%
“…Native human Hp was isolated from plasma using an immunoaffinity column followed by size-exclusion chromatography on an HPLC system using previously described procedures [22].…”
Section: Preparation Of Mouse Mab and Human Hpmentioning
confidence: 99%