Pure water for relative density standard

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
11
0

Year Published

1971
1971
2005
2005

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(12 citation statements)
references
References 4 publications
1
11
0
Order By: Relevance
“…The beam of light reflected onto the sphere was also converged to a point by lens . However, since this beam had been cropped by screen CA, the intensity profile over its cross-section was no longer Gaussian; thus, it is not appropriate to apply (7) to this beam. An analytical treatment of diffraction similar to our case is given in the literature [21].…”
Section: Phase Changes During Propagationmentioning
confidence: 99%
See 2 more Smart Citations
“…The beam of light reflected onto the sphere was also converged to a point by lens . However, since this beam had been cropped by screen CA, the intensity profile over its cross-section was no longer Gaussian; thus, it is not appropriate to apply (7) to this beam. An analytical treatment of diffraction similar to our case is given in the literature [21].…”
Section: Phase Changes During Propagationmentioning
confidence: 99%
“…This purified water was also used for cleaning various components of the measurement apparatus, because this system had the comparatively large capacity of 1,5 litres/min. To purify the sea water, we used an in-house threestage distillation system, which was a close copy of that described by Cox and coworkers [7]. This system continued distillation until the sea water evaporated, and recovered all the water contained in the sea water, so that the isotopic composition of the distillate was the same as that of the original sea water.…”
Section: Purification Systemsmentioning
confidence: 99%
See 1 more Smart Citation
“…Our examinations were performed on water samples purified by the method of Cox et al [17]. The third distillation took place (as also the first two) in contact with the atmosphere and then our third distillate was collected.…”
Section: Methodsmentioning
confidence: 99%
“…Final LSM results for water sample density differences (ρ m,i − ρ m,j )/(g m −3 ) and float density differences Table 4. Some float density differences (ρ 3m − ρ 4m )/(g m −3 ) (column 5) and water density differences (ρ m,i − ρ m,j )/(g m −3 ) (last three columns) as measured with silica floats F 3 and F 4 at t = t m ; column 1 gives sample number in LSM processing, 2-source of water for purification by method of Cox et al [17]: tap water (TW), stored tap water (SW) and de-ionized tap water (DW), 3-date of measurement, 4-water conductivity after examination σ /(µS cm −1 ). (ρ m,i − ρ m,j )/(g m −3 ) are collected in table 4 (based on [15]).…”
Section: Measurementsmentioning
confidence: 99%