1963
DOI: 10.1038/198773b0
|View full text |Cite
|
Sign up to set email alerts
|

Pulsed Laser Operation in a High-pressure Helium Neon Mixture

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

1964
1964
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(3 citation statements)
references
References 2 publications
0
3
0
Order By: Relevance
“…I n multispatial mode operation, continuous powers of about 100 mw have been achieved. By exciting a 1-15 pm He-Ne maser with 1 psec, 35 kv pulses, peak output powers of 84 w have been reported by Boot, Clunie and Thorn (1963). A maser tube 2 cm in diameter, 150 cm long and filled with 5 mmHg of neon and 240 mmHg of helium was used in these experiments and the maximum average powers obtained were 224 mw.…”
Section: Gaseous Optical Maseysmentioning
confidence: 96%
“…I n multispatial mode operation, continuous powers of about 100 mw have been achieved. By exciting a 1-15 pm He-Ne maser with 1 psec, 35 kv pulses, peak output powers of 84 w have been reported by Boot, Clunie and Thorn (1963). A maser tube 2 cm in diameter, 150 cm long and filled with 5 mmHg of neon and 240 mmHg of helium was used in these experiments and the maximum average powers obtained were 224 mw.…”
Section: Gaseous Optical Maseysmentioning
confidence: 96%
“…Peak output powers of 1 W were obtained for the different gas mixtures at wavelengths of 1.153 and 1.069 µm, respectively. Boot et al [453] went on to demonstrate 84 W peak power performance using a pulsed discharge with a 240 Torr He-Ne gas mixture. In 1964, Crocker et al [454] demonstrated stimulated emission at far-IR wavelengths between 23 and 79 µm using a water vapor discharge.…”
Section: Uk Government Defence Establishmentsmentioning
confidence: 99%
“…In principle, one could measure sea depth with a pulsed laser rangefinder, but the propagation even of green light is so very bad that only the depth of clear shallow water could be measured-and that is not exactly a demanding case. Magnetic field strength could in principle be measured by the perturbing effect on optical oscillation frequency of, for instance, the Zeeman effect, 3 or alternatively one might use the laser's ability to produce narrow beams or the ease with which interference effects can be obtained to help in instrumental design.…”
Section: Neonmentioning
confidence: 99%