Pulsed field ablation using focal contact force-sensing catheters for treatment of atrial fibrillation: acute and 90-day invasive remapping results

Abstract: Aims Pulsed field ablation (PFA) has emerged as a promising alternative to thermal ablation for treatment of atrial fibrillation (AF). We report performance and safety using the CENTAURI™ System (Galvanize Therapeutics) with three commercial, focal ablation catheters. Methods and results ECLIPSE AF (NCT04523545) was a prospective, single-arm, multi-centre study evaluating safety and acute and chronic pulmonary vein isolation … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
22
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 28 publications
(29 citation statements)
references
References 60 publications
2
22
0
Order By: Relevance
“…An acute procedural success rate of 100% was achieved with high first-pass isolation (96.8%), with a PAE rate consistent with other ablation technologies and previous STSF studies (4.4%). 20–22 Noteworthy is the absence of oesophageal lesions with systematic endoscopy evaluation confirming tissue selectivity of PFA from pre-clinical data. In addition, good PVI durability was demonstrated, with 86% of PVs remaining isolated at scheduled remapping.…”
Section: Discussionmentioning
confidence: 74%
See 2 more Smart Citations
“…An acute procedural success rate of 100% was achieved with high first-pass isolation (96.8%), with a PAE rate consistent with other ablation technologies and previous STSF studies (4.4%). 20–22 Noteworthy is the absence of oesophageal lesions with systematic endoscopy evaluation confirming tissue selectivity of PFA from pre-clinical data. In addition, good PVI durability was demonstrated, with 86% of PVs remaining isolated at scheduled remapping.…”
Section: Discussionmentioning
confidence: 74%
“…In the recent ECLIPSE AF study involving 82 patients with paroxysmal or persistent AF in Europe, delivery of optimized PFA with CF-sensing solid-tip focal ablation catheters achieved first-pass isolation in 92.2% of PVs. 20 A study investigated a focal ablation catheter able to toggle between RF and PF energy in the treatment of 178 patients with paroxysmal or persistent AF and demonstrated first-pass isolation in 95% of PV pairs. 23 First-pass isolation reported with the STSF RF catheter and index-guided workflow ranges between 73% and 83%.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Monopolar PEF energy is delivered asynchronously using a proprietary biphasic waveform (25 A, 1.6 ms) that minimizes microbubble formation and muscle contraction. 10 The system measures LI between each spline and a central ring electrode. LI information is displayed using a graphical representation of the catheter tip where color and bar length changes represent increasing impedance on each spline (Figure 1D).…”
Section: Ablation Systemmentioning
confidence: 99%
“…Indeed, clinical reports demonstrated frequent pulmonary vein reconnections at relook procedures despite near universal acute isolation at the initial procedure. [8][9][10][11][12][13][14] See Article by Amorós-Figueras et al…”
Section: Editorialmentioning
confidence: 99%