2013
DOI: 10.2166/wst.2013.399
|View full text |Cite
|
Sign up to set email alerts
|

Pulsed corona discharge: the role of ozone and hydroxyl radical in aqueous pollutants oxidation

Abstract: Ozone and hydroxyl radical are the most active oxidizing species in water treated with gas-phase pulsed corona discharge (PCD). The ratio of the species dependent on the gas phase composition and treated water contact surface was the objective for the experimental research undertaken for aqueous phenol (fast reaction) and oxalic acid (slow reaction) solutions. The experiments were carried out in the reactor, where aqueous solutions showered between electrodes were treated with 100-ns pulses of 20 kV voltage an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
26
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 34 publications
(29 citation statements)
references
References 22 publications
3
26
0
Order By: Relevance
“…1. Further details and technical description are presented in our previous publication [25] where the gas-phase ozone concentration in the reactor was also measured, comprising around 5 mg L -1 in air atmosphere, and negligible amounts of oxidants, below 1 mg L -1 , were iodometrically measured in the treated water, which was a binary model solution with notably lower amount of oxidant consuming species than in the presently studied sewage.…”
Section: Plasma Treatment System and Proceduresmentioning
confidence: 99%
See 1 more Smart Citation
“…1. Further details and technical description are presented in our previous publication [25] where the gas-phase ozone concentration in the reactor was also measured, comprising around 5 mg L -1 in air atmosphere, and negligible amounts of oxidants, below 1 mg L -1 , were iodometrically measured in the treated water, which was a binary model solution with notably lower amount of oxidant consuming species than in the presently studied sewage.…”
Section: Plasma Treatment System and Proceduresmentioning
confidence: 99%
“…Here, a maximum progesterone concentration after PCD treatment was measured as 0.072 µg L -1 at 30 W pulse power, while at 250 W the amounts remained at 0.017-0.021 µg L -1 , approximately four times lower at eight times higher pulse power. The disproportion between the rates and applied powers would suggest ozone has a notable role in the reactions [25]. The maximum value corresponds to a progesterone yield of 72 µg kWh -1 .…”
Section: Pharmaceuticals Appearing During Pcd Oxidationmentioning
confidence: 99%
“…For water treatment purposes, the gas-liquid interface where the OH radicals are formed is a crucial environment and the plasma-liquid contact surface area thus makes an important variable 4 6 . In earlier work, a vertical PCD reactor in which the treated solution is allowed to shower through a perforated plate positioned above the plasma zone was employed to generate a large plasma-liquid contact surface area 6 .…”
Section: Introductionmentioning
confidence: 99%
“…In earlier work, a vertical PCD reactor in which the treated solution is allowed to shower through a perforated plate positioned above the plasma zone was employed to generate a large plasma-liquid contact surface area 6 . Increasing this contact surface improves the oxidation energy efficiency mainly due to the enhanced action of superficial OH radicals 4 , 6 . Although OH radical activity at the plasma-liquid interface is evident, it is extinguished in complete absence of O 2 4 .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation