Pulse Skipping Switching mode: a case study of Efficiency Improvement on a switched-capacitor DC-DC step-up converter IC

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2008
2008
2012
2012

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 4 publications
0
5
0
Order By: Relevance
“…Extra circuitry like non-overlapping clock generators [21] and level-shifters that are needed to implement the CK k switching clock signals shown in Fig. 1 must also be included in the simulation phase leading to large and slow simulations (a couple of hours using a dedicated workstation with four 1 GHz UltraSPARC III processors with 8,192 Mbytes of RAM memory and Spectre simulator from Cadence Ò in liberal mode) to obtain just some milliseconds of the steady-state V out waveform for a fixed configuration of the design parameters. Moreover, if a parametric analysis (just for one parameter) is carried out to observe the charge pump's behavior, then the time needed to obtain just some milliseconds of the steady-state V out waveform increases up to a couple of full days.…”
Section: Simulation Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Extra circuitry like non-overlapping clock generators [21] and level-shifters that are needed to implement the CK k switching clock signals shown in Fig. 1 must also be included in the simulation phase leading to large and slow simulations (a couple of hours using a dedicated workstation with four 1 GHz UltraSPARC III processors with 8,192 Mbytes of RAM memory and Spectre simulator from Cadence Ò in liberal mode) to obtain just some milliseconds of the steady-state V out waveform for a fixed configuration of the design parameters. Moreover, if a parametric analysis (just for one parameter) is carried out to observe the charge pump's behavior, then the time needed to obtain just some milliseconds of the steady-state V out waveform increases up to a couple of full days.…”
Section: Simulation Resultsmentioning
confidence: 99%
“…This kind of switching mode can be easily implemented using the pulse skipping frequency regulator (PSFR) circuit shown in Fig. 15 which reduces the switching frequency f s skipping unneeded switching clock pulses while at the same time regulates the steady-state V out voltage [8,27].…”
Section: Pulse Skipping Switching Modementioning
confidence: 99%
See 1 more Smart Citation
“…A conventional method to regulate voltage in a switched-capacitor based DC/DC converter is to use pulse-frequency modulation (PFM) [3] or burst mode modulation [4]. These control techniques can improve light load efficiency, but suffering from tones in the frequency spectrum.…”
Section: Introductionmentioning
confidence: 99%
“…In some applications, an additional regulator is needed to regulate the DC-DC converter and deliver a stable output voltage. There are mainly three different regulation schemes [28][29][30]. i) Pulse-Skip Regulation Figure 2.11 Pulse-skip Regulation In the pulse-skip regulation scheme, the regulation of output voltage is achieved by skipping the unnecessary pulses.…”
Section: Regulation Schemesmentioning
confidence: 99%