2019
DOI: 10.1088/1748-0221/14/07/p07017
|View full text |Cite
|
Sign up to set email alerts
|

Pulse shape discrimination performance of a pixelated plastic scintillator (EJ-299-34) for a coded-aperture based dual particle imaging system

Abstract: The pulse shape discrimination performance of a pixelated organic plastic scintillator has been investigated. The scintillator has been built using 169 plastic scintillator blocks (arranged into a 13 × 13 square array) of 2.8 × 2.8 × 15 mm3 each. The scintillator was coupled with a single-channel photomultiplier tube. The scintillator was exposed to a mixed-field environment provided by 252Cf and its pulse shape discrimination capabilities are presented in this paper. Initial results revealed t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(10 citation statements)
references
References 35 publications
0
10
0
Order By: Relevance
“…Thus, the light loss might cause a lower FOM value. Nevertheless, because intrinsic particle separation of the scintillator is achieved 5 , the low sampling rate ADCs were capable of performing satisfactory PSD using the pixelated stilbene-SiPM array module.
Figure 6 ( a ) The overall detector PSD plot for 1,500,000 pulses produced by the stilbene-SiPM module with a threshold of 50 keVee by measuring a 3.5 × 10 5 n/s 252 Cf spontaneous fission source at 75 cm distance and a 137 Cs source producing 30.16 μR/h at 30 cm distance.
…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Thus, the light loss might cause a lower FOM value. Nevertheless, because intrinsic particle separation of the scintillator is achieved 5 , the low sampling rate ADCs were capable of performing satisfactory PSD using the pixelated stilbene-SiPM array module.
Figure 6 ( a ) The overall detector PSD plot for 1,500,000 pulses produced by the stilbene-SiPM module with a threshold of 50 keVee by measuring a 3.5 × 10 5 n/s 252 Cf spontaneous fission source at 75 cm distance and a 137 Cs source producing 30.16 μR/h at 30 cm distance.
…”
Section: Resultsmentioning
confidence: 99%
“…The experiments verified that the coded aperture-based DPI can provide effective neutron-source imaging with a limited number of counts and therefore rapid imaging for relatively intense or proximate neutron sources. This can be compared with H2DPI from the University of Michigan 5 that has a quoted localization time of 30 min for the neutron image of a 1.2 × 10 7 n/s 252 Cf source at 58.4 cm from the center of system.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…This is because the stilbene scintillator pixels used here are not only smaller than those used in the reference studies, but also the pixels of SiPM used here have smaller active areas than the PMT. Nevertheless, because intrinsic particle separation of the scintillator is achieved [5], the low sampling rate ADCs were capable of performing satisfactory PSD using the pixelated stilbene-SiPM array module.…”
Section: Resultsmentioning
confidence: 99%
“…The experiments verified that the coded aperture-based DPI can provide effective neutron-source imaging with a limited number of counts and therefore rapid imaging for relatively intense or proximate neutron sources. This can be compared with H2DPI from the University of Michigan [5] that has a quoted localization time of 30 minutes for the neutron image of a 1.2 × 10 7 n/s 252 Cf source at 58.4 cm from the center of system. Similar to neutron image evaluation, we estimated the quality of gamma-ray images by measuring the 137 Cs producing 6.4 μR/h at 100 cm from the hand-held DPI.…”
Section: Resultsmentioning
confidence: 99%