2015
DOI: 10.1515/mms-2015-0029
|View full text |Cite
|
Sign up to set email alerts
|

Pulse Sequence Shaper For Radiospectroscopy And Relaxation Methods In NQR

Abstract: A pulse sequence shaper for the pursuance of the research using a wide spectrum of radiospectroscopy and relaxation methods in NQR is proposed. The distinctive feature of this product is its implementation with the application of a multi-functional programmable frequency synthesizer suitable for high-speed amplitude and phase manipulations.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 2 publications
0
5
0
Order By: Relevance
“…This pulse activates the pulse counter in the sequence Pulse_counter:inst4, the source code of which from the output “ROM[4..0]” is fed to the non-volatile memory module ROM_module: inst17, and changing the level at the output “Pulse_out” leads to the activation of the video pulse generator Pulse_former:inst9. The operating principle of the latter is described in detail in [ 19 ]. Code words with data on the duration of the 90° pulse and the pause between the first and second pulses in the sequence are sent from the main interface controller (inst5 in Figure 3 ) to the inputs “Pulse[15..0]” and “Pause[26..0]”, respectively.…”
Section: Methods Of Configuring Devices Based On the Syntax Of Modeling Dynamic Modes Of Logical Structuresmentioning
confidence: 99%
See 3 more Smart Citations
“…This pulse activates the pulse counter in the sequence Pulse_counter:inst4, the source code of which from the output “ROM[4..0]” is fed to the non-volatile memory module ROM_module: inst17, and changing the level at the output “Pulse_out” leads to the activation of the video pulse generator Pulse_former:inst9. The operating principle of the latter is described in detail in [ 19 ]. Code words with data on the duration of the 90° pulse and the pause between the first and second pulses in the sequence are sent from the main interface controller (inst5 in Figure 3 ) to the inputs “Pulse[15..0]” and “Pause[26..0]”, respectively.…”
Section: Methods Of Configuring Devices Based On the Syntax Of Modeling Dynamic Modes Of Logical Structuresmentioning
confidence: 99%
“…The key difference of the proposed solution is the ability to readjust the phase of the signal generated by the first channel with an accuracy of 1 degree and synchronize the initial phase of the generated radio pulses, with the leading edges of the video pulses arriving at the RF_pulse_In input from the output of the pulse train programmer ( Figure 5 ). The latter makes it possible to avoid the time-increasing errors of establishing the duration of the 90° and 180° excitation pulses of NQR, which occur when using classical incoherent techniques of radio pulse formation [ 19 , 27 ]. The modules LPM_Constant:inst15—LPM_Constant:inst18 and LPM_MUX:inst11 are used to provide quadrature phase manipulation.…”
Section: Methods Of Configuring Devices Based On the Syntax Of Modeling Dynamic Modes Of Logical Structuresmentioning
confidence: 99%
See 2 more Smart Citations
“…In more detail, this block diagram and the principle of operation are described in paper [1]. Some parts and units of the proposed device are described in detail in papers [14][15][16][17][18][19].…”
Section: Measuring Setup For the Study Of Nqrmentioning
confidence: 99%