2016 Diagnostic of Electrical Machines and Insulating Systems in Electrical Engineering (DEMISEE) 2016
DOI: 10.1109/demisee.2016.7530468
|View full text |Cite
|
Sign up to set email alerts
|

Pulse sequence analysis of corona discharge at DC voltage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 5 publications
0
5
0
Order By: Relevance
“…It is a recognized fact that in most dc applications, when increasing the amplitude of the applied voltage, negative corona occurs first, at lower voltage, as proved in the experimental work of Fuangpian et al [23]. With the same atmospheric conditions, electrode and gap geometry, the spark breakdown condition under negative dc supply occurs at higher voltage than under positive dc supply, as proved in the experimental works of Pihera et al [30] and Maglaras et al [33]. Factors such as temperature, humidity, atmospheric pressure, electrode distance, or radius influence the corona inception voltage and discharge behavior [19].…”
Section: Coronas In Atmospheric Airmentioning
confidence: 87%
See 2 more Smart Citations
“…It is a recognized fact that in most dc applications, when increasing the amplitude of the applied voltage, negative corona occurs first, at lower voltage, as proved in the experimental work of Fuangpian et al [23]. With the same atmospheric conditions, electrode and gap geometry, the spark breakdown condition under negative dc supply occurs at higher voltage than under positive dc supply, as proved in the experimental works of Pihera et al [30] and Maglaras et al [33]. Factors such as temperature, humidity, atmospheric pressure, electrode distance, or radius influence the corona inception voltage and discharge behavior [19].…”
Section: Coronas In Atmospheric Airmentioning
confidence: 87%
“…The integration of a growing number of renewable sources has led to the widespread use of more HVDC systems [30]. The discharge behavior under dc and ac supply is different, mainly due to the effects of the space charge generated.…”
Section: Coronas In Atmospheric Airmentioning
confidence: 99%
See 1 more Smart Citation
“…This paper deals with basic "Q-t PSA" diagrams which are not so frequently published as "Q-Q PSA" diagrams as the outcome of the experimental measurements and PSA plots. "Q-t PSA" provides more information about PD activity [10,11,16,19,20].…”
Section: Pulse Sequence Analysismentioning
confidence: 99%
“…Several studies [1][2][3][4][5][6] dealt with the PD issues in general. Some of the recent studies [2,[7][8][9][10] were focused on the PD under DC from a specific point of view-pulse sequence analysis (PSA). The analysis seems to be a method to distinguish the PD type at DC voltage instead of the phase-resolved characteristics used at AC voltage.…”
Section: Introductionmentioning
confidence: 99%