2007
DOI: 10.3171/foc.2007.22.4.3
|View full text |Cite
|
Sign up to set email alerts
|

Pulse pressure waveform in hydrocephalus: what it is and what it isn't

Abstract: Object Apart from its mean value, the pulse waveform of intracranial pressure (ICP) is an essential element of pressure recording. The authors reviewed their experience with the measurement and interpretation of ICP pulse amplitude by referring to a database of recordings in hydrocephalic patients. Methods The database contained computerized pressure recordings from 2100 infusion studies (either lumbar o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

3
20
1
1

Year Published

2010
2010
2016
2016

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 33 publications
(25 citation statements)
references
References 25 publications
3
20
1
1
Order By: Relevance
“…AMPmean is therefore likely to be low in these patients. The theory that these patients are less likely to respond to shunt surgery is in agreement with our previous findings [32], and it is potentially explained by these patients suffering from large ventricles due to brain atrophy rather than NPH [12].…”
Section: Discussionsupporting
confidence: 91%
“…AMPmean is therefore likely to be low in these patients. The theory that these patients are less likely to respond to shunt surgery is in agreement with our previous findings [32], and it is potentially explained by these patients suffering from large ventricles due to brain atrophy rather than NPH [12].…”
Section: Discussionsupporting
confidence: 91%
“…En los primeros parece más relacionada con los cambios en el volumen sanguíneo cerebral y en los segundos con las cifras de PIC media 2 . Algunos autores han demostrado que la respuesta positiva a la derivación es superior en HCA en aquellos pacientes en los que la amplitud del pulso de la PIC es mayor 7,3 , así como que dicha amplitud se reduce tras la colocación de dispositivos de derivación de LCR 6,3 . En los pacientes de esta serie se aprecia cómo el aumento de la PIC media se correlaciona con mayores diferencias entre los componentes sistólico y diastólico de la PIC.…”
Section: -323unclassified
“…There exists indirect evidence that certain characteristics of ICP slow waves may contain useful information for correctly diagnosing NPH and predicting shunt response. It was recently found that increased ICP pulse pressure amplitude has a predictive value for shunt response [9,57]. In this section, we describe our recent attempt [13] to detect and separate periods of ICP slow waves (BW, "B-wave") from those of flat or nearly flat ICP (NW, "no wave") in an overnight ICP recording.…”
Section: Morphological Icp Waveform Characteristics During Slow Wavesmentioning
confidence: 99%