2020
DOI: 10.26434/chemrxiv.11930031
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Psi4 1.4: Open-Source Software for High-Throughput Quantum Chemistry

Abstract: <div> <div> <div> <p>Psi4 is a free and open-source ab initio electronic structure program providing Hartree–Fock, density functional theory, many-body perturbation theory, configuration interaction, density cumulant theory, symmetry-adapted perturbation theory, and coupled-cluster theory. Most of the methods are quite efficient thanks to density fitting and multi-core parallelism. The program is a hybrid of C++ and Python, and calculations may be run with very simple text f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
51
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
1
1

Relationship

3
5

Authors

Journals

citations
Cited by 47 publications
(51 citation statements)
references
References 0 publications
0
51
0
Order By: Relevance
“…For comparison to conventional linear response results, we also carried out EOM-CCSD/cc-pVDZ excitation-energy calculations, which are included as stick spectra. These results were obtained using the Psi4 code 66 with the same frozen-core approximation. of the relevant CC equations in single precision were adequate for most applications, and a limited number of "cleanup" iterations in double-precision could recover higher accuracy.…”
Section: Computational Detailsmentioning
confidence: 99%
“…For comparison to conventional linear response results, we also carried out EOM-CCSD/cc-pVDZ excitation-energy calculations, which are included as stick spectra. These results were obtained using the Psi4 code 66 with the same frozen-core approximation. of the relevant CC equations in single precision were adequate for most applications, and a limited number of "cleanup" iterations in double-precision could recover higher accuracy.…”
Section: Computational Detailsmentioning
confidence: 99%
“…19 This calculation, which we term a "serial relaxed scan", is a standard feature in several widely used quantum chemistry and geometry optimization codes. [20][21][22][23][24][25][26][27][28] The serial relaxed scanning approach has some major drawbacks. 29 For one, the resulting optimized structures are dependent on the chosen sequence of calculations, such as the direction of the one-dimensional scan.…”
Section: E(φ Abcdmentioning
confidence: 99%
“…These calculations were performed within the QCArchive infrastructure that provides TorsionDrive calculations as a service, as described in Section 4.2. Energies and gradients were calculated using the B3LYP-D3(BJ) functional and DZVP basis optimized for DFT 42 as implemented in the Psi4 software package, 23 and optimizations were carried out using the geomeTRIC software. 28 The results show that a 1D torsion scan started from a conformation where the hydroxyl groups are facing in opposite directions (4b upper) will fail to find the lowest energy con- 3.4 Generalized dihedral scanning and restricted grid improper -marked by red in above chemical structure) for characterizing PES of a molecular motor at B3LYP-D3/3-21G level of theory.…”
Section: Multiple Initial Structuresmentioning
confidence: 99%
“…By contrast, the energy profile generated by TorsionDrive is more symmetrical, as ex- in the Psi4 software package, 23 and optimizations were carried out using the geomeTRIC software. 28 The results show that a 1D torsion scan started from a conformation where the hydroxyl groups are facing in opposite directions (4b upper) will fail to find the lowest energy conformer.…”
Section: E(φ Abcdmentioning
confidence: 99%
“…These calculations were performed within the QCArchive infrastructure that provides TorsionDrive calculations as a service, as described in Section 4.2. Energies and gradients were calculated using the B3LYP-D3(BJ) functional and DZVP basis optimized for DFT 42 as implemented in the Psi4 software package, 23 and optimizations were carried out using the geomeTRIC software. 28 The results show that a 1D torsion scan started from a conformation where the hydroxyl groups are facing in opposite directions (4b upper) will fail to find the lowest energy con- 3.4 Generalized dihedral scanning and restricted grid TorsionDrive has several additional features for flexibility in setting scanning coordinates for different molecular systems.…”
Section: Torsion Grid Pointmentioning
confidence: 99%