2019 1st Global Power, Energy and Communication Conference (GPECOM) 2019
DOI: 10.1109/gpecom.2019.8778541
|View full text |Cite
|
Sign up to set email alerts
|

Providing an IEC 61850 Counterpart of the Trusty Multimeter - Approaching the Maintenance Procedures for IEC 61850 Substations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 2 publications
0
4
0
Order By: Relevance
“…SCN based in IEC 61850 contains several IEDs that perform well in terms of testing, protection, and control [30,31]. Each device is connected to intelligent hubs (LNs) and individual data queries following the IEC 61850 standard.…”
Section: Iec 61850-based Substation Communication Networkmentioning
confidence: 99%
“…SCN based in IEC 61850 contains several IEDs that perform well in terms of testing, protection, and control [30,31]. Each device is connected to intelligent hubs (LNs) and individual data queries following the IEC 61850 standard.…”
Section: Iec 61850-based Substation Communication Networkmentioning
confidence: 99%
“…13 Index Terms-current differential protection, hardware-inthe-loop testing, IEC 61850 GOOSE message, IEDs, interoperability the lack of interoperability among IEDs relay from different vendors has led to several issues, including delays in commissioning, increased costs, and reduced system efficiency. These significant challenges of interoperability are due to the differences in the implementation of the standard by multi vendors [14,15]. This is particularly relevant for PTRF differential protection schemes, which require the cooperation of multiple devices from different vendors to provide system power stability and protection [16,17].…”
Section: Introductionmentioning
confidence: 99%
“…During maintenance at an Electrical Substation, fault currents are injected to the protection relays to ensure that the system is still functioning properly [1]. The maintenance test will generate alarms, control signals and therefore create traffic in the communication network [1].…”
Section: Introductionmentioning
confidence: 99%
“…During maintenance at an Electrical Substation, fault currents are injected to the protection relays to ensure that the system is still functioning properly [1]. The maintenance test will generate alarms, control signals and therefore create traffic in the communication network [1]. One of the scenarios in this paper is to simulate maintenance traffic on an IEC 61850 protocol based communication network and monitor whether the Generic Object Oriented System (GOOSE), Sample Values (SV), Generic Substation State Events (GSSE) and manufacturing message specification (MMS) messaging over the network meet the IEC 61850 standard transfer time requirements.…”
Section: Introductionmentioning