Prototype of a primary calibration system for measurement of radon activity concentration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 22 publications
0
6
0
Order By: Relevance
“…The detector effi ciency is 15% for Pu-239 line with 20% uncertainty. For each screen of diffusion battery, plate of impactor, and backup fi lter used, the effi ciency was comparable with that using standard high-purity germanium detector [26,27]. Therefore, the absolute alpha activity on the wire screen or the cascade impactor plate can be easy calculated.…”
Section: Methodsmentioning
confidence: 92%
“…The detector effi ciency is 15% for Pu-239 line with 20% uncertainty. For each screen of diffusion battery, plate of impactor, and backup fi lter used, the effi ciency was comparable with that using standard high-purity germanium detector [26,27]. Therefore, the absolute alpha activity on the wire screen or the cascade impactor plate can be easy calculated.…”
Section: Methodsmentioning
confidence: 92%
“…A 60-minute diffusion mode was standard for our version of the AlphaGUARD PQ2000Pro equipment. This AlphaGUARD was calibrated using a NIST calibration source (Mostafa et al, 2016). Using the NIST source, the calibration error (including source activity error, random errors during measurements, etc.)…”
Section: Experimental Set-up and Proceduresmentioning
confidence: 99%
“…The absolute detection efficiency for the 214 Bi line (609.3 keV) was found to be 2.05 x 10 -2 ±3% for the 95% confidence interval. The uncertainty in this detection efficiency was obtained by the least squares method using the experimental data of the energy dependence detection efficiency in the Spectra Line Ultimate Gamma Lab program (Mostafa et al, 2015(Mostafa et al, , 2016. The fit quality for this polynomial efficiency was directly tested in each experiment by measuring the total absorption peaks of the Cs standard source with the activity 10.64 ±0.19 kBq (P = 0.99 and k = 2.58), traceable to the same set of calibration sources, E γ = 661.66 keV (close to the energy line of 214 Bi, i.e., 609.3 keV).…”
Section: Radioactivity Measurements Using Germanium Detectorsmentioning
confidence: 99%
See 2 more Smart Citations