Prototype imaging x-ray fluorescence spectrometer based on microchannel plate optics

Abstract: A new form of imaging x-ray fluorescence spectrometer, based on a microchannel plate relay optic and a charge coupled device x-ray detector, produces elemental mapping over an instantaneous field of view of 24 mm square without the need to scan either the sample or x-ray beam. We describe the design of a prototype responsive over the energy range of 370 eV-10 keV, its quantitative calibration, demonstration of 0.7 mm spatial resolution and the spectrometer's use in the analysis of geological samples.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2005
2005
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(11 citation statements)
references
References 23 publications
0
11
0
Order By: Relevance
“…MPOs are sometimes referred to as “lobster‐eye” optics when used in a curved geometry for X‐ray astronomy . In the 1:1 imaging configuration, the optic is flat and equidistant between the sample surface and the CCD . X‐ray photons are collimated and focused as a result of total reflections at grazing incidence inside the channels.…”
Section: Methodsmentioning
confidence: 99%
“…MPOs are sometimes referred to as “lobster‐eye” optics when used in a curved geometry for X‐ray astronomy . In the 1:1 imaging configuration, the optic is flat and equidistant between the sample surface and the CCD . X‐ray photons are collimated and focused as a result of total reflections at grazing incidence inside the channels.…”
Section: Methodsmentioning
confidence: 99%
“…These X-ray sources are small, 0.015 m in diameter with a height of 0.01 m, and powered by a 9 V dry battery. Price et al (2004) have devised an interesting Xray fluorescence imaging spectrometer that can map analytes and X-ray intensity ratio. It was demonstrated, however, that Ba, Ca, Cr, Fe, K, Pb, Si, Sr, Ti and Zn could be detected in glasses (Ida and Kawai 2004a).…”
Section: Neutron Activation Analysis Atomic Absorption and X-ray Flumentioning
confidence: 99%
“…The authors also reported measuring Ba, Br, Co, Cr, I, Mn and Pb at the mg l -1 level in solution, after preconcentration on ion-exchange resins, using the same type of detectors (Ida and Kawai 2004b). Price et al (2004) have devised an interesting Xray fluorescence imaging spectrometer that can map analytes and X-ray intensity ratio. They mapped the Mg/Si X-ray intensity ratio of a square anorthosite slab measuring 0.25 m x 0.25 m. The spatial resolution seems somewhat limited, but the authors argue that the optical system used could be improved.…”
Section: Neutron Activation Analysis Atomic Absorption and X-ray Flumentioning
confidence: 99%
“…These direct imaging methods are more suited to situations where mechanical simplicity is critical. Among the different imaging devices that can be used, square-pore micro-channel plate X-ray optics (MPO), sometimes referred to as "Square Multi channel plate optics" , "Multi-pore optics" or "lobster-eye optics" is one of the most attractive because of its efficiency given by the corner cube effect [9][10][11][12], in particular when compared with straight polycapillary optics [13,14] used for 1:1 imaging. Planar MPOs, to which this study will be restricted, offer a magnification of 1 to cover a surface area commensurate with the size of the detector, and provide an additional degree of freedom, compared to spherical MPOs, with the possibility of changing the working distance without changing the magnification.…”
Section: Introductionmentioning
confidence: 99%