2022
DOI: 10.1016/j.memsci.2022.120510
|View full text |Cite
|
Sign up to set email alerts
|

Proton blockage PVDF-co-HFP-based anion exchange membrane for sulfuric acid recovery in electrodialysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 18 publications
(13 citation statements)
references
References 42 publications
0
12
0
Order By: Relevance
“…Consequently, the migration rate of K + into the base compartment decreased, resulting in a reduced acid production rate. Although the concentration of KOH in the base compartment slightly increased, it was not significantly enhanced due to the leakage of H + ions. , …”
Section: Resultsmentioning
confidence: 89%
See 1 more Smart Citation
“…Consequently, the migration rate of K + into the base compartment decreased, resulting in a reduced acid production rate. Although the concentration of KOH in the base compartment slightly increased, it was not significantly enhanced due to the leakage of H + ions. , …”
Section: Resultsmentioning
confidence: 89%
“…Although the concentration of KOH in the base compartment slightly increased, it was not significantly enhanced due to the leakage of H + ions. 38,39 The influence of different volume ratios on the current efficiency and SEC is shown in Figure 10. As the volume ratio of the acid−base compartment increased from 1:2 to 2:1, the current efficiency increased from 54.9 to 68.1%.…”
Section: Effect Of Feed Concentration On the Bmed Processmentioning
confidence: 99%
“…Three typical characteristic regions are observed in Figure a. The first stage is the ohmic region, where the current is proportional to the voltage; the second stage is the plateau zone, where the current approaches the limit; the third stage is the overlimit region, where the current rises sharply and the phenomenon of concentration polarization occurs. , As displayed in Figure b, with the increased amount of Bpy-CHO introduced, the limiting current density of PVA-Bpy-CHO- X AEMs is enhanced from 11.45 to 20.96 mA·cm –2 . In conclusion, the as-prepared AEMs present high limited current density, indicating their potential to be applied in ED desalination.…”
Section: Resultsmentioning
confidence: 93%
“…Yu et al modified poly(vinylidene fluoride- co -hexafluoropropylene) (PVDF- co -HFP) with 1-vinylimidazole before crosslinking with 1,4-dibromobutane to create a sequence of proton blockage cross-linking in an AEM. 356 The PVDF- co -HFP-based AEM was reported to have an apparent asymmetric structure on its two sides, with a smooth and dense surface and a rough and porous surface. The fluorinated backbone of AEM's asymmetric structure and hydrophobicity result in greater proton blocking performance, higher electrical efficiency, and less energy-intensive acid recovery.…”
Section: Recycling and Regenerationmentioning
confidence: 99%