2019 4th International Symposium on Instrumentation Systems, Circuits and Transducers (INSCIT) 2019
DOI: 10.1109/inscit.2019.8868468
|View full text |Cite
|
Sign up to set email alerts
|

Protocol and reference material for measuring the nanoantenna enhancement factor in Tip-enhanced Raman Spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 13 publications
0
7
0
Order By: Relevance
“…A potential alternative method has been presented theoretically in the literature that uses the TERS approach curve on an ideal two-dimensional scattering surface. The tip radius is also measured using a topographic alignment grid . This approach may provide characterization of TERS systems with reduced sample dependence but has not been confirmed experimentally.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…A potential alternative method has been presented theoretically in the literature that uses the TERS approach curve on an ideal two-dimensional scattering surface. The tip radius is also measured using a topographic alignment grid . This approach may provide characterization of TERS systems with reduced sample dependence but has not been confirmed experimentally.…”
Section: Resultsmentioning
confidence: 99%
“…The tip radius is also measured using a topographic alignment grid. 62 This approach may provide characterization of TERS systems with reduced sample dependence but has not been confirmed experimentally.…”
Section: ■ Introductionmentioning
confidence: 99%
“…Second, aligning laser to the tip apex and using a topographic orientation grid enables a real and fast examination of the tip apex radius. Third, the tip approach curve is fitted . As a reference sample, Sacco et al use thiol nanopatterns (suitable for STM and AFM) .…”
Section: Discussionmentioning
confidence: 99%
“…To make the results more comparable, standardized methods for the calibration of spectrometers and measurements with reference samples are necessary. 77 Neto et al 153 developed a multistep protocol for measuring the improvement factor of TERS using a reference material for the calibration of confocal Raman and TERS (STM and AFM). First, the scanning confocal optical microscope must be focused on graphene (a strong Raman signal).…”
Section: The Main Experiments and Applications To Datementioning
confidence: 99%
See 1 more Smart Citation