2021
DOI: 10.14203/j.mev.2021.v12.28-37
|View full text |Cite
|
Sign up to set email alerts
|

Proteus ISIS simulation for power factor calculation using zero crossing detector

Abstract: One of the important parameters for electrical systems is the power factor (cos phi), which is the ratio of the real power (watt) to the apparent power (volt ampere). The best cos phi value is between 0.85 to 1. A resistive load causes the voltage and current in equal phase angle, while the inductive load causes the current to lag behind the voltage. On the other hand, the capacitive load causes the current to precede the voltage (leading). A simulation to determine the power factor of an electrical network ca… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 7 publications
0
2
0
Order By: Relevance
“…For all three MUXs, they will be 74LS153 chips [10]. As for the flip-flop used in the control unit, it is better to choose 74LS74, whose power consumption could be optimized [11]. And the counter selected in the circuit should be a synchronous chip, which could be 74LS109 [12].…”
Section: Build-up and Layout For The Circuitmentioning
confidence: 99%
“…For all three MUXs, they will be 74LS153 chips [10]. As for the flip-flop used in the control unit, it is better to choose 74LS74, whose power consumption could be optimized [11]. And the counter selected in the circuit should be a synchronous chip, which could be 74LS109 [12].…”
Section: Build-up and Layout For The Circuitmentioning
confidence: 99%
“…ZCP detection circuits are complex and require more accurate detection; due to this complexity few works are carried out by avoiding ZCP, such as soft-switching control without zero-crossing detection for the cascaded buck-boost converters [16]. Detection of ZCP using Proteus ISIS software with a microcontroller is proposed in [17] for power factor correction and a trigger angle on the SCR trigger for DC motor speed control is for the rocket launch angle adjuster. A simple detection method for the ZCP of converter current using a saturable transformer for use in high-current and high-frequency pulse-width modulated power electronic converter applications is proposed in [18].…”
Section: Introductionmentioning
confidence: 99%