2022
DOI: 10.1186/s40644-022-00453-7
|View full text |Cite
|
Sign up to set email alerts
|

Prostate MRI using a rigid two-channel phased-array endorectal coil: comparison with phased array coil acquisition at 3 T

Abstract: Background To compare image quality, lesion detection and patient comfort of 3T prostate MRI using a combined rigid two-channel phased-array endorectal coil and an external phased-array coil (ERC-PAC) compared to external PAC acquisition in the same patients. Methods Thirty three men (mean age 65.3y) with suspected (n = 15) or biopsy-proven prostate cancer (PCa, n = 18) were prospectively enrolled in this exploratory study. 3T prostate MRI includin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 30 publications
0
5
0
Order By: Relevance
“…The preference for 3T without ERC is consistent with the results of a survey by the Society of Abdominal Radiology (SAR) prostate disease-focused panel (DFP) [ 6 ]. The rare use of ERC after its application for decades may be explained by patient discomfort, increased cost, possible susceptibility artifacts, and the need for software to correct the high signal intensity ratio bias [ 17 ].…”
Section: Discussionmentioning
confidence: 99%
“…The preference for 3T without ERC is consistent with the results of a survey by the Society of Abdominal Radiology (SAR) prostate disease-focused panel (DFP) [ 6 ]. The rare use of ERC after its application for decades may be explained by patient discomfort, increased cost, possible susceptibility artifacts, and the need for software to correct the high signal intensity ratio bias [ 17 ].…”
Section: Discussionmentioning
confidence: 99%
“…At the same magnetic field strength, it is of no surprise that there are numerous studies that validate the proposed superiority in SNR that results from using an ERC 30–32 . Few studies have evaluated CNR, although Ullrich et al 31 did not observe improved discrimination between benign and cancerous prostate.…”
Section: Scanner Factorsmentioning
confidence: 92%
“…29 At the same magnetic field strength, it is of no surprise that there are numerous studies that validate the proposed superiority in SNR that results from using an ERC. [30][31][32] Few studies have evaluated CNR, although Ullrich et al 31 did not observe improved discrimination between benign and cancerous prostate. The expected improvement in image quality, as rated by radiologists on a 1 to 5 Likert scale, has been shown for DWI 32,33 and T2-WI 34 but certain studies have also reported no superiority with either set up.…”
Section: Erc Usementioning
confidence: 99%
See 2 more Smart Citations