Prospects of hard X-ray polarimetry with Astrosat-CZTI

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
67
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
4

Relationship

3
6

Authors

Journals

citations
Cited by 44 publications
(67 citation statements)
references
References 25 publications
0
67
0
Order By: Relevance
“…In this work, we have adopted the same analysis procedure as described in the above references, but have conducted the polarisation analysis of the two emission episodes separately. The Compton events are identified by first selecting the doublepixel events that occurred within a 40µs time window, and secondly, by filtering those double-pixel events against the various Compton kinematics criteria (Chattopadhyay et al 2014). The Compton lightcurve of GRB 160325A in 100-380 keV energy range is shown in Figure 7.…”
Section: Polarisation Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…In this work, we have adopted the same analysis procedure as described in the above references, but have conducted the polarisation analysis of the two emission episodes separately. The Compton events are identified by first selecting the doublepixel events that occurred within a 40µs time window, and secondly, by filtering those double-pixel events against the various Compton kinematics criteria (Chattopadhyay et al 2014). The Compton lightcurve of GRB 160325A in 100-380 keV energy range is shown in Figure 7.…”
Section: Polarisation Measurementsmentioning
confidence: 99%
“…Despite the small number of Compton events, the second emission episode, on the other hand, is found to be highly polarised at > 3σ confidence level ( Figure 8) for two parameters of interest. This is because for on-axis GRB detection, the polarisation sensitivity of the instrument is high (Chattopadhyay et al 2014). In Figure 8, 2-D contours of confidence intervals of 68%, 90%, 99% (3 σ) and 99.9% (3.7 σ) of polarisation fraction and polarisation angle are shown 7 .…”
Section: Polarisation Measurementsmentioning
confidence: 99%
“…The hard X-ray polarimetric capability of CZTI was extensively investigated by Chattopadhyay et al 7 , using Monte Carlo simulations. It was also experimentally verified before launch using polarized X-rays and more importantly, using unpolarized X-rays 8 .…”
Section: Hard X-ray Polarizationmentioning
confidence: 99%
“…The double pixel events within the photon tagging time window of 40 µs which satisfy the Compton kinematics are identified as valid Compton events. The validity of the Compton event selection and the polarization measurement capability of CZTI have been established by detailed simulation and experimental studies during ground calibration of CZTI (Chattopadhyay et al 2014;Vadawale et al 2015). The first onboard validation of CZTI polarimetry was obtained with the detection of polarization of GRB 160131A (Vadawale et al 2016) and GRB 151006A .…”
Section: Polarization Measurement -Further Evidence For the Second Pumentioning
confidence: 99%